DVB Series Direct Vent Gas Fireplace
54D0701
9
cleARANces
cleARANces to coMBustIBles
W
ARNING
Follow these instructions carefully to ensure safe installation. Failure
to follow instructions exactly can create a fire hazard.
the appliance cannot be installed on a carpet, tile or other
combustible material other than wood flooring. If installed on carpet
or vinyl flooring, the appliance shall be installed on a metal, wood
or noncombustible material panel extending full width and depth of
the appliance.
7”
5”
11”
3”
12"
8"
6”
2”
FP2204
mantel clearances
Wall
Stud
Insulation
Board
Standoff
FP04
Top of Exhaust
Louvers
side View
1"
2
56O
”
3"
4"
1
56O
”
2
56O
”
45°
FP2093
mantel side clearance
Wall
Combustible
Material Area
Side of Fire-
place Opening
FP093
top View
Figure 5 -
Mantel Clearances
71” Minimum
11” Minimum
12”
Max.
Min. 4”
From Either
Side Wall
FP2248
mantel clearances
Figure 4 -
Clearances
Ceiling
Combustible Mantel
FP48
W
ARNING
Never obstruct or modify the air inlet or
outlet grilles (louvers). this may create a
fire hazard.