background image

17

UVLC Series

UVLC Supreme Vent Free Gas Logs 

(continued)

  Ref.     Description 

UVLC18 

UVLC24 

UVLC30

  1g.  Log #V43 Front Left 

n/a 

n/a 

20004893

  1h.  Log #V44 Front Right 

n/a 

n/a 

20004894

  2a.  Burner Supply w/Orifices - Natural 

20003050 

20000329 

20000329

  2b.  Burner Supply w/Orifices - LP 

20003687 

20000318 

20000318

 

3.  3/8” Flex Tubing 

3304176 

3304176 

3304176

 

4.  Volcanic Rock 

20000198 

20000198 

20000198

  5a.  Damper Stop 

3030176 

3030176 

3030176

  5b.  Damper Stop 

4304045 

4304045 

4304045

 

6.  Elbow Fitting 1/2” NPT (F) x 3/8” Flare 

7523184 

7523184 

7523184

 

7.  Lava Rock (Burner) 

57897 

57897 

57897

 

8.  Switch 

1601597 

1601597 

1601597

 

9.  Andiron Assembly 

20005295 

20005295 

20005295

  10.  Swivel Door - Painted 

20005340 

20005345 

20005345

  11.  Back Plate 

20003023 

20000321 

20000321

  12.  Right Side Grate - Painted 

20005338 

20005338 

20005338

  13.  Left Side Grate - Painted 

20005339 

20005339 

20005339

  14.  Fettle - Painted 

20005344 

20005343 

20005343

  15a.  Pilot Assembly - LP 

55465 

55465 

55465

  15b.  Pilot Assembly - Natural 

55464 

55464 

55464

  16.  Piezo Ignitor 

20000062 

20000062 

20000062

  17.  Piezo Ignitor Cable 

20000101 

20000101 

20000101

  18.  Ignitor Electrode 

Order Pilot 

Order Pilot 

Order Pilot

  19a.  Valve - LP 

10000242 

10000242 

10000242

  19b.  Valve - Natural 

10000235 

10000235 

10000235

  20.  ON/OFF Extension (Not shown) 

20000007 

20000007 

20000007

  21.  HI/LO Extension (Not shown) 

20000006 

20000006 

20000006

  22.  Pilot Bracket Assembly 

20003530 

20003530 

20003530

  23a.  Pilot Shield 

20003499 

-- 

--

  23b.  Pilot Shield 

-- 

20003500 

20003500

  24.  Burner Housing Assembly 

20003028 

20000277 

20000277

Summary of Contents for Woodland UVLC18RN

Page 1: ...RBON MONOXIDE POISONING MAY LEAD TO DEATH When used without fresh air vent free log sets may give off carbon monoxide an odorless poisonous gas Some people pregnant women people with heart or lung dis...

Page 2: ...ve been designed and tested to operate safely when installed according to the installation instruc tions contained in this manual Read all instructions before starting the installation The vent free g...

Page 3: ...opening a window or otherwise providing additional ventilation to the area Min Fireplace Dimensions A B C D Logset Gas Front Rear Overall Overall Pressure w c Manifold Min Input Max Input Setting Wid...

Page 4: ...actory built replace or ventless rebox enclosure State provincial or local codes may only allow opera tion of this appliance in a vented con guration Check your state provincial or local codes If unve...

Page 5: ...ent free Gas Heater Vented Gas Heater Other Gas Appliances Do not include Direct vent appliances as these use outdoor air for combustion and vent to the outdoors Modern construction standards have res...

Page 6: ...each 4 000 BTU hr For further information on ventilation guidelines and siz ing speci cations follow the National Fuel Gas Code NFPA 54 ANSI Z223 1 NFPA 54 Section 5 3 If the total BTU hour used by th...

Page 7: ...ion Preparation A 1 2 inch gas supply line must be supplied to the rebox In most cases this will require drilling a gas line access hole through the masonry wall The gas supply line should then be sea...

Page 8: ...the damper locking bracket Attach the damper stop with the screws provided Fig 6 NOTE Some of the early units may not have the holes in the end of the damper locking bracket If this is the case use t...

Page 9: ...of the replace to a height of at least 20 and the full width of the replace A combustible at mantel shelf can be no closer than 38 from the top of the replace opening Fig 7b With Hood If a hood is in...

Page 10: ...lve ON and carefully check all gas con nections for leaks with a soapy water solution or a sniffer DO NOT TEST FOR LEAKS WITH AN OPEN FLAME Upon completing your gas line connection a small amount of a...

Page 11: ...wall switch to the valve termnals Remote Wall Switch Optional Model GWSK 1 Thread wire through the electrical knockout located on either side of the replace Do not cut the wire or insulation on metal...

Page 12: ...normal You may wish to have the windows open to dissipate any odors during the curing process Flame Appearance To obtain proper operation it is imperative that the pilot and main burner ame characteri...

Page 13: ...NG smell all around the heater area for gas Be sure to smell next to the oor because some gas is heavier than air and will settle on the oor WHAT TO DO IF YOU SMELL GAS Do not try to light any replace...

Page 14: ...Replace piezo ignitor For air in the lines Thermopile needs a minimum of 325mV All wiring connections Replace thermopile Thermocouple needs a minimum of 14mV Defective valve turn to pilot meter should...

Page 15: ...ali ed eld service person Always keep the appliance area clear and free from combustible materials gasoline and other ammable vapors and liquids Never obstruct the ow of combustion and ventilation air...

Page 16: ...ci cations prices and discontinue colors and products at any time without notice UVLC Supreme Vent Free Gas Logs 1 Complete Log Set 20003423 20000327 20003428 1a Back Log 20003425 7583198 20003430 1b...

Page 17: ...el Door Painted 20005340 20005345 20005345 11 Back Plate 20003023 20000321 20000321 12 Right Side Grate Painted 20005338 20005338 20005338 13 Left Side Grate Painted 20005339 20005339 20005339 14 Fett...

Page 18: ...enamel in Midnight Black AC110 Remote WAll Switch 5 7 99 djt AC100 FIREPLACE HOOD 3 29 99 DJT AC111 Fireback from VErmont 5 7 99 djt NOTE If any of the original wire as supplied with the appliance mu...

Page 19: ...de chaleur de la chambre combustion et du br leur en c ramique de tout produit CFM Corporation sont garanties pour la vie de l acheteur d origine le tout sujet une preuve d achat et aux conditions et...

Page 20: ...CFM Corporation 2695 Meadowvale Blvd Mississauga Ontario Canada L5N 8A3 800 668 5323 www cfmcorp com CFM Corporation...

Reviews: