NVC Series B-Vent 

20000194

Remote Controls

Optional remote control units are available to control 
different functions of the appliance.
 

Model 

Function(s) Controlled

 

RC1

 

ON/OFF

 

RC2

 

ON/OFF and Temperature

 

IMTFK

 

Wall mounted thermostat control

Ceramic Refractory Panels

Ceramic refractory panels are available to line the fire-
box area. 
 

Unit 

Kit Model

 

NVC36 

NV36CR

 

NVC39 

NV39CR

 

NVC43 

NV43CR

Take care when handling the refractory panels as they 
are fragile until held in place and supported.

Installation

, refer to Figures 24 & 25

1.  Remove the window frame assembly.
2.  Remove the logs.
3.  Place the lower supports for the side refractory pan-

els on the base of the firebox. Place each support so 
that the slotted hole fits over the forward screw head 
along the edge of the base.

4.  Lay the angular base panels in place on the floor of 

the firebox on either side of the burner housing as-
sembly.

5.  Loosely attach the top adjustable tabs to the studs 

located in the top of the firebox toward the front cor-
ners.

6.  Place the rear refractory panel in place. Locate the 

'small brick' edge of the panel into the two small 
supports on the back panel just above the rear log 
support.

7.  Slide the side refractory panels into place to hold 

the rear panel secure. Adjust the top adjustable tabs 
to hold the side panel against the firebox wall and 
secure the tab. Repeat the procedure on the other 
side.

8.  Replace the logs and window frame assembly.

For aesthetic purposes we recommend lining up the 
horizontal mortar lines.

Adjustable 

Tab

Side 

Panel

Floor 

Refractory 

Panel

Lower Side Supports

FP1193

Fig. 24

  Install ceramic refractory panels.

Adjustable 

Tab

Side 

Panel

Floor 

Refractory 

Panel

Rear Refrac-

tory Panel

Rear Panel 

Support 

Brackets

Firebox 

Back

Rear Log Support

FP1194

Fig. 25

  Place the rear panel on rear support brackets.

Arched Door Front

The arched door front kit is designed to visually en-
hance the appearance of the NVC fireplace. 
To install the door front simply position the magnets as 
shown in Figure 26. Place the arched door into position 
and peel off the plastic. (Fig. 27)

FP1195

Arched door front

2/27/02   djt

FP1195

Fig. 26

  Install magnets.

Magnets

Summary of Contents for NVC36

Page 1: ...st be performed by a quali ed installer service agency or the gas supplier Do not store or use gasoline or other ammable vapors and liquids in the vicinity of this or any other appliance FOR YOUR SAFE...

Page 2: ...ne Installation 8 Remote Switch Installation 8 Alternate Switch Location 8 EB 1 Electrical Box 9 Install Venting System Flashing and Termination 9 Operating Instructions Glass Information 11 General M...

Page 3: ...Remove any plastic from trim parts before turning the replace ON It is normal for replaces fabricated of steel to give off some expansion and or contraction noises during the start up or cool down cy...

Page 4: ...l for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size GAS VENT DIRECTLY BELOW KEEP CLEAR OF ALL OBSTRUCTIONS...

Page 5: ...ons Ref NVC36 NVC39 NVC43 Framing Dimensions A 36 927 mm 39 1003 mm 43 1105 mm B 34 883 mm 35 889 mm 37 953 mm C 14 362 mm 16 419 mm 16 419 mm Appliance Dimensions D 36 914 mm 39 991 mm 43 1092 mm E 2...

Page 6: ...C D E V W X Y Z Fireplace CFM146 DV Mantel Chart 7 5 01 sta Ref Mantel Ref Mantel From Top Shelf Depth of Comb Chamber V 10 254 mm A 19 495 mm W 8 203 mm B 17 444 mm X 6 152 mm C 15 394 mm Y 4 101 mm...

Page 7: ...ove sea level For elevations above 4 500 feet 1 370m in USA installations must be in accordance with the current ANSI Z223 1 NFPA 54 and or local codes having jurisdiction In Canada please consult pro...

Page 8: ...gas control is equipped with a captured screw type pressure test point therefore it is not necessary to pro vide a 1 8 test point up stream of the control When using copper or ex connector use only ap...

Page 9: ...crew polarized of the socket assembly 6 Connect the white wire of the power line to the chrome screw of the socket assembly 7 Connect the ground wire of the supply line to the green screw of the socke...

Page 10: ...11 12 97 Venting Runs 40 38 36 34 32 30 28 26 24 22 20 18 16 14 12 8 9 10 11 12 3 4 5 6 7 Horizontal Run in feet Vertical Run in feet Measured from floor of unit tocenter of horizontal vent pipe A A V...

Page 11: ...h a non ammonia household cleaner and warm water gas replace glass cleaner is recom mended After initial use glass should be cleaned two or three times during heating season Clean glass after rst two...

Page 12: ...13 or 14 L O HI Turn counterclockwise to decrease flame height Turn clockwise to increase flame height HV102 Honeywell hi lo knob 4 5 99 djt Fig 13 Flame adjustment knob for Honeywell valve HV102 Tur...

Page 13: ...Any foreign objects in the venting system except those designed speci cally for the venting system may cause spillage of ue gases To inspect the venting system make sure the main gas valve is off Remo...

Page 14: ...all around the heater area for gas Be sure to smell next to the oor because some gas is heavier than air and will settle on the oor WHAT TO DO IF YOU SMELL GAS Do not try to light any replace Do not t...

Page 15: ...the sensor by pressing the reset pin between the two wire terminals Fig 18 CAUTION The components may still be hot Light the replace and check for downdrafts Operate the replace in the normal manner...

Page 16: ...ting or buckling Take protective actions to shield cable and boot from excessive temperatures Check for 24VAC across MV MV PV terminals If no voltage replace module Check electrical connections betwee...

Page 17: ...o Ignitor Supply Line Hooked Up Shutoff Valve Open Pilot Stays Lit For Air In The Lines Thermopile Needs A Min 325mv Adjust Pilot Flame Height All Wiring Connections Replace Thermopile Thermocouple Ne...

Page 18: ...ir in the Lines Thermopile Needs a Minimum 325Mv Adjust Pilot Flame Height All Wiring Connections Replace Thermopile Thermocouple Needs a Minimum of 14Mv Pilot Lights With Piezo Ignitor YES YES YES YE...

Page 19: ...ment It is important to keep the burner and the burner compartment clean At least once per year the logs and lava rock ember material should be removed and the burner compartment vacuumed and wiped ou...

Page 20: ...CFM Corporation reserves the right to make changes in design materials speci cations prices and discontinue colors and products at any time without notice NVC36 39 43 For Units B32H00 B32I00 B33A00 B3...

Page 21: ...7587 57587 16b Valve SIT VN 57588 57588 57588 17a Valve SIT EN 57884 57884 57884 17b Valve SIT EP 57883 57883 57883 18 Manifold Tubing w Fittings 57318 57318 57318 19 Transformer VN VP EN VP 7522409 7...

Page 22: ...0194 NVC36 39 43 continued Ref Description NVC36 NVC39 NVC43 40a Valve Honeywell VS8421 Nat 10001782 10001782 10001782 40b Valve Honeywell VS8421 LP 10001759 10001759 10001759 41 Vent Safety Switch 10...

Page 23: ...nt access 4 The power supply may be connected in 2 ways Method A route the 6 1 8m lead tted to the unit to a conveniently located wall socket Method B If the EB 1 receptacle box Pt ZA1200 was correctl...

Page 24: ...toward the front cor ners 6 Place the rear refractory panel in place Locate the small brick edge of the panel into the two small supports on the back panel just above the rear log support 7 Slide the...

Page 25: ...mation for the trim kits applicable to this model appliance Decorative Bay Windows When tting the Bay Window Kits the original front frame glass assembly MUST remain in place The Bay Window kit is tte...

Page 26: ...26 NVC Series B Vent 20000194...

Page 27: ...damage is found to be the fault of the manufacturer repairs will be authorized at no charge to the customer parts and or labor Any part and or component replaced under the provisions of this warranty...

Page 28: ...NVC36RFP 29 4 NVC36EN 28 5 NVC36EP 28 5 NVC39RN 26 4 NVC39RP 26 4 NVC39RFN 26 4 NVC39RFP 26 4 NVC39EN 25 6 NVC39EP 25 6 NVC43RN 27 9 NVC43RP 27 9 NVC43RFN 27 9 NVC43RFP 27 9 NVC43EN 27 1 NVC43EP 27 1...

Reviews: