Page 1: ...life FOR YOUR SAFETY Installation and service must be performed by a quali ed installer service agency or the gas supplier Do not store or use gasoline or other am mable vapors and liquids in the vici...

Page 2: ...bustibles 5 Mantels 5 Mantel Chart 5 Hearth 5 Framing Finishing 6 Final Finishing 6 Gas Speci cations 6 Gas Inlet Manifold Pressures 6 High Elevations 6 Parts Identi cation and Chase Installation 7 Ga...

Page 3: ...on air must not be obstructed in any way 11 Whether the appliance is installed directly on carpeting vinyl tile or any combustible material other than wood this appli ance must be installed on a metal...

Page 4: ...1016mm 36 914mm 3 76mm 1 6 m m 37 953mm 13mm 5 4 1 3 7 2 m m 19 502mm 21 533mm 40 1029mm 7 191mm 6 165mm 7 191mm 7 191mm Outside Air Electrical Access Gas Line Access WFP623 GBR36 2 11 98 Rough Openin...

Page 5: ...70 DV Builder Front View O N M L K J F G H I Mantel Leg CFM164a Mantel Leg Chart 06 22 01 sta Black Surround Face Side of Combustion Chamber CFM170 CFM164 Hearth Extension A hearth extension in front...

Page 6: ...struct or modify the air inlet outlet grilles in any manner Finish the wall with the material of your choice Refer to Figures 2a and 2b for speci c clearances when install ing a combustible mantel or...

Page 7: ...essure equal to or less than 1 2 psig 3 45 kPa The appliance and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test...

Page 8: ...to a conveniently located wall receptacle box 2 Attach wire to switch and install switch into recep tacle box Attach cover plate to switch 3 Connect wiring to gas valve Refer to Figure 6 or 7 dependin...

Page 9: ...ion excess wire completely within the EB1 Attach the cov erplate to the replace Fig 8 FP580 INSTA VENT FREE EB1 JUNCTION BOX 11 18 97 Outside Electrical Box Front Of Unit Inside Front Of Unit FP580 Fi...

Page 10: ...ed within the vent system using a maximum of two 45 degree elbows B FP567a Fig 11 Venting con gurations when installing 36GSKBB FP567 Fig 10 Venting con gurations FP567 NVBR NVBC VENTING RUNS 11 12 97...

Page 11: ...hold cleaner and warm water we recommend gas replace glass cleaner After that the glass should be cleaned two or three times during each heating season depending on the circumstances present Clean gla...

Page 12: ...on gas valve standing pilot only FP390 LO H I Turn counterclockwise to increase flame height Turn clockwise to lower flame height FP390 FLAME ADJUSTMENT KNOB 11 21 96 Flame Characteristics It is impor...

Page 13: ...smell all around the heater area for gas Be sure to smell next to the oor because some gas is heavier than air and will settle on the oor WHAT TO DO IF YOU SMELL GAS Do not try to light any replace D...

Page 14: ...d to push in or turn the gas control knob Never use tools If the knob will not push in or turn by hand do not try to repair it call a quali ed service technician Force or attempting repair may result...

Page 15: ...eded All wiring connections Replace Piezo Ignitor Thermodisk For Air in the lines Thermopile needs a minimum 325mV Adjust pilot flame height All wiring connections Replace Thermopile Thermocouple need...

Page 16: ...ight All Wiring connections Replace thermopile Thermocouple needs a minimum 14mV Defective valve Turn to pilot meter should read greater than 100mV If not replace Thermodisk Pilot Lights with Piezo Ig...

Page 17: ...n cable for signs of melting or buckling Take protective actions to shield cable and boot from excessive temperatures Check for 24VAC across MV MV PV terminals If no voltage replace module Check elect...

Page 18: ...r shutter should be set to 1 16 open 6 Install manifold to burner tube 7 Reinstall burner tube and retaining bracket Burner ori ce and air shutter conversion complete FC102 Air shutter 7 21 99 djt Bur...

Page 19: ...ube enters the pilot as sembly Tighten tting if necessary 3 Light the main burner and check for leaks around the new pressure regulator assembly Tighten screws if necessary 4 With the main burner ON c...

Page 20: ...y a quali ed technician In order to properly clean the burner and pilot assem bly turn off the gas to the unit open the glass door if used remove logs exposing the burner and pilot assembly Clean all...

Page 21: ...es the right to make changes in design materials speci cations prices and discontinue colors and products at any time without notice GBR36 Ref Description GBR36 1 Log Set Assembly 20005291 1a Back Log...

Page 22: ...37 17 Door Track 3061104 18 Remote Switch Kit 53875 19 Lava Rock Package 55255 20 Bag of Embers 7060109 21 Valve Cover 3078116 22a Electronic Valve Natural 57884 22b Electronic Valve LP 57883 23a Elec...

Page 23: ...e appliance model number 2 The serial number 3 A description of the part Should you need additional information beyond what your dealer can furnish contact CFM Specialty Home Products 410 Admiral Blvd...

Page 24: ...Optional remote control units are available to control different functions of the appliance Model Function s Controlled MRC1 ON OFF MRC2 ON OFF and Temperature MRC3 ON OFF and Temperature control with...

Page 25: ...25 GBR Series B Vent Gas Fireplace 7412955...

Page 26: ...26 GBR Series B Vent Gas Fireplace 7412955...

Page 27: ...f upon inspection the damage is found to be the fault of the manufacturer repairs will be authorized at no charge to the customer parts and or labor Any part and or component replaced under the provis...

Page 28: ...410 Admiral Blvd Mississauga Ontario Canada L5T 2N6 905 670 7777 www majesticproducts com www vermontcastings com CFM Specialty Home Products...