DVHVAC36

10001195

A)   Flat on wall  

B)   Cross corner 

C)  **Island 

D)  *Room divider 

E)   *Flat on wall corner  F)   Chase installation 

Y)  6" minimum

NOTE (Fig. 1): 

 

** Island (C) and Room Divider (D) installation is possible as 
long as the horizontal portion of the vent system (X) does not 
exceed 20' (6m).  See details in Venting Section.
*  When you install your CFM Corporation fireplace in (D) Room 
divider or (E) Flat on wall corner positions (Y), a minimum of 6" 
(153mm) clearance must be maintained from the perpendicular 
wall and the front of the fireplace.

Locating Your Gas Fireplace

Y

D

F

X

X

A

E

B

C

Y

LU584-3

locating unit

DVHVAC

8/19/03

LU584-3

Fig. 1

  Locate gas fireplace.

Clearance to Combustibles

  Back .............................................................. 0" (0 mm)
  Side ............................................................... 0" (0 mm)
  Floor .............................................................. 0" (0 mm)
  Top ................................................................ 0" (0 mm)
  Flue ...................................................... 2" (51 mm) Top
   ..............................................1" (25 mm) Sides/Bottom

Unit Assembly

The DVHVAC36 is shipped in three cartons. The first 
carton contains the fireplace cabinet. The second car-
ton contains the air circulating blower section and the 
third carton contains the coil cabinet. Unpack all three 
sections before following the assembly instructions:
1.  Place the air circulating blower section onto the left 

side of the fireplace cabinet.  (Fig. 3)

2.  Ensure the damper plate below the blower assembly 

works freely without binding. Rotate it downwards 
and ensure that it returns to a closed position.

3.  Secure air circulating blower section to fireplace 

cabinet using 8 of the #8 screws provided.  

4.  Remove the access panel on the front of the air cir-

culating blower section by removing the #10-24 nuts. 
Remove the jack plug from the air circulating blower 
motor by gently depressing tab.

5.  Attach the metal conduit from the fireplace cabinet 

to the 7/8" diameter hole in the side of the air cir-
culating blower section using the nut provided.  Do 
not feed the two yellow wires which are outside the 
conduit through the hole. Insert the terminal on the 
white wire (common) into position 1 on the jack plug.  
Insert the terminal on the black wire (cooling speed) 
into position 2 on the jack plug. Insert the terminal on 
the red wire (heating speed), into position 3, 4 or 5 
on the jack plug.  If unsure, select position 4 on the 
jack plug for heating speed and adjust if necessary.  
If desired the speed selections can be changed later.  
Refer to Figure 8 Wiring Diagram.

WARNING:

  Ensure that all three wires are properly 

inserted into jack plug, even if an optional air condi-
tioner is not to be used.

6.  Reinstall jack plug into motor and replace access 

panel.

7.  Place the coil cabinet section onto the right side of 

the fireplace cabinet so the access panel faces the 
front of the unit. (Fig. 3) Remove the access panel 
and secure the coil cabinet to the fireplace cabinet 
using 8 of the #8 screws provided.  

8.  Connect the 1/4" quick connect terminals of the two 

yellow wires from the fireplace cabinet to the high 
limit safety control located on the top of the coil cabi-
net.

FP1399

DVHVAC 

fireplace assy

8/20/03 

Blower Section

Coil Cabinet

Fireplace Cabinet

FP1399

Fig. 3

  DVHVAC36 unit assembly.

Summary of Contents for DVHVAC36

Page 1: ...cannot reach your gas supplier call the re department WARNING IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED EXACTLY A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE PERSONAL INJURY OR LOSS...

Page 2: ...eral Venting 9 General Venting Information Termination Location 10 General Information Assembling Vent Pipes 11 Twist Lock Pipes 11 How to Use the Vent Graph 12 Sidewall Venting Graph 12 Corner Instal...

Page 3: ...at the gas valve and pilot light are turned off before you attempt to clean this re place 7 The venting system chimney of this replace should be checked at least once a year and if needed your venting...

Page 4: ...ci cations Ref DVHVAC36 Ref DVHVAC36 A 36 914 mm N 9 245 mm B 34 870 mm O 6 175 mm C 21 533 mm P 2 58 mm D 33 838 mm Q 2 51 mm E 63 1621 mm R 3 97 mm F 70 1780 mm S 4 102 mm G 16 410 mm T 1 2 13 mm H...

Page 5: ...Remove the access panel on the front of the air cir culating blower section by removing the 10 24 nuts Remove the jack plug from the air circulating blower motor by gently depressing tab 5 Attach the...

Page 6: ...depth to suit facing material adjustable to 1 2 5 8 or 3 4 depths Fig 4 5 Screw through slotted holes in drywall strip and then screw into pre drilled holes on replace side Meas ure from face of repl...

Page 7: ...f any part of it has been under water Immediately call a quali ed service technician to inspect the replace and replace any part of the control which has been under water Gas Inlet Manifold Pressures...

Page 8: ...test point therefore it is not necessary to pro vide a 1 8 test point up stream of the control When using copper or ex connector use only approved ttings When using black iron pipe always provide a un...

Page 9: ...BLUE R W1 G Y GND CHASSIS GND 24 VAC RTN 24 VAC HOT TH TP PILE TH PILE THERMOPILE GAS VALVE TP TH TP TH EMERGENCY HEAT SWITCH 14 YELLOW 15 BLUE 13 BLUE 12 YELLOW RED WHITE L1 L2 TP TH TH LIMIT 16 YELL...

Page 10: ...3 91cm J Clearance to nonmechanical air supply inlet 6 15cm for appliances 10 000 6 15cm for appliances to building or the combustion air inlet to any Btuh 3kW 12 30cm for 10 000 Btuh 3kW 9 other app...

Page 11: ...suggest putting a lubricant Vaseline or similar on the male end of the twist lock pipe prior to assembly TWL100 Twist Lock Pipe 3 12 99 djt Male End Female End Screw Holes TWL100 Fig 11 Twist lock pip...

Page 12: ...se applications Refer to Venting Components listed for different installation requirements The maximum horizontal distance between the rear of the appliance and the outside face of the rear wall is 20...

Page 13: ...rmination 4 collar into the 4 pipe then the 7 collar into the 7 pipe Do not force the venting into position If the pipes do not line up with the termina tion collars disassemble elbows or pipes and re...

Page 14: ...alled in either the vertical or horizontal run When one 1 90 elbow is installed directly onto another off the back of the replace the maximum horizontal vent length is 36 914 mm Fig 19 For each 45 elb...

Page 15: ...4 100 Vent Opening 2 99 djt Vent Opening for Combustible Wall 9 240 mm 9 240 mm Fireplace Hearth Framing Detail Vent Opening for Noncombustible Wall 7 190 mm VO584 100 Fig 22 Locate vent opening on wa...

Page 16: ...uirement STEP 7 Support the horizontal pipes every 36 914 mm with metal pipe straps Make sure the horizontal vent pipe is installed on a level horizontal plane STEP 8 Re check the replace to make sure...

Page 17: ...pe Straps Every 3 914mm CFM148 Fig 30 Support straps for horizontal runs Up to two 2 45 elbows may be used within the horizontal run For each 45 elbow used on the hori zontal level the maximum horizon...

Page 18: ...and 7 collars of vertical vent termination and install If there is a room above ceiling level restop spacers must be installed on both the bottom and the top side of the ceiling joists If an attic is...

Page 19: ...ustable length 7TDVP3566 35 to 64 adjustable length Pipe sections for vertical or horizontal venting Model 7TDVP8 Model 7TDVP12 Model 7TDVP24 Model 7TDVP36 Model 7TDVP48 Firestop Spacer Model 7DVFS At...

Page 20: ...other airborne particles to cling to the glass surface Also initial paint curing may deposit a slight lm on the glass It is therefore recommended the glass FP1405 DVHVAC remove glass frame 8 03 Clamps...

Page 21: ...to the ON position This will turn on the replace burner in a low re condition The unit will provide heat to the room in which the replace is installed When power is restored toggle the emergency heat...

Page 22: ...and logs 2 Place refractory side supports so that the hole ts over the screw head on the rebox oor 3 Place refractory base sides on the oor of the re box 4 Attach adjustable tabs packed with refracto...

Page 23: ...the oor because some gas is heavier than air and will settle on the oor WHAT TO DO IF YOU SMELL GAS Do not try to light any replace Do not touch any electric switch Do not use any phone in your buildi...

Page 24: ...An interrupter block not supplied must be used to conduct this test 3 Pilot burning no gas to A Thermostat or wires defective Check wall switch and wires for proper connections main burner Valve knob...

Page 25: ...tem consist of burner tube gas ori ce pilot assembly thermopile millivolt gas valve Most of these components may require only an occasional checkup and cleaning and some may require adjustment If repa...

Page 26: ...C parts 7 02 4a b 1e 1f 1d 1c 1b 1a 1195 CFM Corporation reserves the right to make changes in design materials speci cations prices and discontinue colors and products at any time without notice DVHV...

Page 27: ...t 54273 8b Ori ce Pilot Prop 54272 9 Pilot 3 Way 10001295 10 Pilot Tubing w ttings 53211 11 Manifold Tubing w ttings 57318 12 Thermocouple 53373 13 Thermopile 51827 14 Electrode Ignitor w cable 100012...

Page 28: ...ang bay window assembly over existing window frame assembly Do not remove existing window frame as sembly 6 Re install upper louvre assembly Remove all plastic from brass trims 7 Bottom brass trim is...

Page 29: ...29 DVHVAC36 10001195...

Page 30: ......

Page 31: ...mageisfoundtobethefaultofthemanufacturer repairs will be authorized at no charge to the customer parts and or labor Any part and or component replaced under the provisions of this warranty is covered...

Page 32: ...EnerGuide Ratings Steady State D O E Fireplace Ef ciency Fan OFF Fan ON AFUE DVHVAC36RN 76 83 84 77 1 DVHVAC36RP 76 84 85 77 1 410 Admiral Blvd Mississauga Ontario Canada L5T 2N6 800 668 5323 www cfmc...

Reviews: