background image

3

DVB4136 Direct Vent Gas Fireplace

20012322

Installation & Operating Instructions

This gas appliance should be installed by a qualified installer, 
preferably NFI or WETT (Canada) certified, in accordance with 
local building codes and with current 

CSA-B149.1

 Installation 

codes for Gas Burning Appliances and Equipment.  If the unit is 
being installed in a mobile home, the installation should comply 
with the current 

CAN/CSA Z 240.4

 code. For U.S.A Installations 

follow local codes and/or the current 

National Fuel Gas Code. 

ANSI Z223.1/NFPA 54.
FOR SAFE INSTALLATION AND OPERATION PLEASE 
NOTE THE FOLLOWING:

1 .  This fireplace gives off high temperatures and should be 

located out of high traffic areas and away from furniture 
and draperies.

2.   Children and adults should be alerted to the hazards of the 

high surface temperatures of this fireplace and should stay 
away to avoid burns or ignition of clothing.

3.  

CAUTION: Due to high glass surface temperature chil-
dren should be carefully supervised when  in the same 
room as fireplace.

Proposition 65 Warning:

 Fuels used in gas, woodburning or 

oil fired appliances, and the products of combustion of such 
fuels, contain chemicals known to the State of California to 
cause cancer, birth defects and other reproductive harm.
California Health & Safety Code Sec. 25249.6

IMPORTANT:

PLEASE READ THE FOLLOWING CAREFULLY

Remove any plastic from trim parts before turning the 
fireplace ON.
It is normal for fireplaces fabricated of steel to give off 
some expansion and/or contraction noises during the 
start up or cool down cycle. Similar noises are found 
with your furnace heat exchanger or car engine.  It is 
not unusual for your CFM Corporation gas fireplace to 
give off some odor the first time it is burned. This is due 
to the manufacturing process.

Please ensure that your room is well ventilated

-open all windows.

It is recommended that you burn your fireplace for at 
least ten (10) hours the first time you use it. If the op-
tional fan kit has been installed, place the fan switch in 
the “OFF” position during this time.

WARNING: Check with your electronics manufac-
turer before installing a television or other electronic 
device above this fireplace.

11.  When fireplace is installed directly on carpeting, vinyl tile 

or any combustible material other than wood, this fireplace 
must be installed on a metal or wood panel extending the 
full width and depth of the fireplace.

12.  This fireplace requires adequate ventilation and combus-

tion air to operate properly.

13.  This fireplace must not be connected to a chimney flue 

serving a separate solid fuel burning fireplace.

14.  When the fireplace is not in use it is recommended that the 

gas valve be left in the OFF position.

This appliance may be installed in an aftermarket 
permanently located, manufactured home or mobile 
home, where not prohibited by local codes.
This appliance is only for use with the type of gas 
indi-cated on the rating plate. This appliance is not 
convertible for use with other gases, unless a certi-
fied kit is used.

DVB4136

Certified To

ANSI Z21.88b-2008 / CSA 2.33b-2008 

Vented Gas Fireplace Heater

�������

���������

�����

������������

������������

������

�������������

�����

���������������

���������������

4.   Under no circumstances should this fireplace be modified. 

Parts removed for servicing should be replaced prior to 
operating this fireplace again.

5.  Installation and any repairs to this fireplace must be 

performed by a qualified installer, service agency or gas 
supplier. A professional service person should be contacted 
to inspect this fireplace annually. Make it a practice to have 
all of your gas fireplaces checked annually. More frequent 
cleaning may be required due to excess lint and dust from 
carpeting, bedding material, etc.

6.  Control compartments, burners and air passages in this 

fireplace should be kept clean and free of dust and lint. 
Make sure the gas valve and pilot light are turned off before 
you attempt to clean this fireplace.

7.  The venting system (chimney) of this fireplace should be 

checked at least once a year and if needed your venting 
system should be cleaned.

8.  Keep the area around your fireplace clear of combustible 

materials, gasoline and other flammable vapor and liquids. 
This fireplace should not be used as a drying rack for cloth-
ing, nor should Christmas stocking or decorations be hung 
in the area of it.

9.  Under no circumstances should any solid fuels (wood, coal, 

paper or cardboard etc.) be used in this fireplace.

10.  The flow of combustion and ventilation air must not be 

obstructed in any way. 

Summary of Contents for DVB4136

Page 1: ...try to light any appliance Do not touch any electric switch do not use any phone in your building Immediately call your gas supplier from your neighbor s phone Follow the gas supplier s instructions...

Page 2: ...13 How to Use the Vent Graph 14 Rear Wall Vent Application Installation 15 Vertical Sidewall Application Installation 16 Below Grade Installation 20 Vertical Through the Roof Application Installation...

Page 3: ...r before installing a television or other electronic device above this replace 11 When replace is installed directly on carpeting vinyl tile or any combustible material other than wood this replace mu...

Page 4: ...terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size GAS VENT DIRECTLY BELOW KEEP CLEAR OF ALL OBSTR...

Page 5: ...Recessed Nailing Flange 15 381 mm 3 92 mm Electrical Access 40 1016 mm 45 1162 mm 5 8 1 6 m m 6 4 1 6 4 5 m m 6 152 mm 20 524 mm Fireplace Dimensions Installed as Rear Vent Fig 2 Fireplace speci catio...

Page 6: ...cating Your Fireplace LU584 1 A Flat on wall B Cross corner C Island D Room divider E Flat on wall corner F Chase installation Y 0 minimum Check minimum if mantel leg is used NOTE Fig 3 Island C and R...

Page 7: ...Gas Speci cations Max Min Gas Input Input Model Fuel Control BTU h BTU h DVB4136RN Natural Gas Millivolt Hi Lo 30 000 18 500 DVB4136RP Propane Millivolt Hi Lo 30 000 17 000 DVB4136IN Natural Gas 6V DC...

Page 8: ...pen ame for leak testing The replace valve must not be subjected to any test pressures exceeding 1 2 psi Isolate or disconnect this or any other gas appliance control from the gas line when pressure t...

Page 9: ...ps below FP580 INSTA VENT FREE EB1 JUNCTION BOX 11 18 97 OUTSIDE Electrical Box FRONT OF UNIT INSIDE FRONT OF UNIT FP580 Fig 10 EB 1 receptacle 1 Unscrew the retaining screw from the EB 1 base plate F...

Page 10: ...eplace gas ket Fig 13 7 Secure outer collar adapter to unit with the round collar on top secure with 10 screws NOTE Be sure not to damage any gasket material FP1030a Outer Collar Adapter Flue Pipe 7 0...

Page 11: ...ch incorporates the use of ex venting shall have an inclining slope from the unit of 1 25 mm per 24 610 mm There must not be any obstruction such as bushes gar den sheds fences decks or utility buildi...

Page 12: ...e to service regulator vent outlet 3 91cm 3 91cm J Clearance to nonmechanical air supply inlet 6 15cm for appliances 10 000 6 15cm for appliances to building or the combustion air inlet to any Btuh 3k...

Page 13: ...mperature Sealant Hose Clamp FP1471 Fig 17 Apply high temperature sealant to 4 and 7 pipes Outside Corner Inside Corner Termination Clearances Termination clearances for buildings with combustible and...

Page 14: ...intersection draw a vertical line to the bottom of the graph 3 Select the indicated dimension and position the replace in accordance with same EXAMPLE A If the vertical dimension from the oor of the u...

Page 15: ...listed for different installation requirements The maximum horizontal distance between the rear of the appliance or end of the transition elbow in a corner application and the outside face of the rear...

Page 16: ...the appliance collar and bend to 45 DO NOT exceed 45 Fig 26 Install the 7 vent pipe in the same manner as Step 2 NOTE There must be a 1 2 13 mm rise in a 12 305 mm length of ex vent FP1473 corner fle...

Page 17: ...maximum number of 90 elbows per side wall installation is three 3 Fig 27 If a 90 elbow is tted directly on top of the replace ange the maximum horizontal vent run before the termination or a vertical...

Page 18: ...and cut zero clearance sleeve parts to proper length MAXIMUM 12 305 mm Assemble sleeve and attach to restop with 8 sheet metal screws supplied Install restop assembly Fig 34 Zero clearance sleeve is o...

Page 19: ...ngs on the 4 ex vent pipe When installing the spacer springs around the 4 pipe stretch the spring to approximately 15 381 mm wrap the spring around the pipe and interlock the ends of the spacer spring...

Page 20: ...w Well Gravel Drain BG402a Fig 39 Below grade installation Zero Clearance Sleeve if required A minimum of 24 610 mm vertical pipe must be installed when using the 7TDVSNORK Kit 24 610mm Minimum Screws...

Page 21: ...c Insulation Shield 7DVAIS into position and secure Fig 43 7 Install roof support Fig 44 and roof ashing making sure upper ange is below the shingles Fig 46 8 Install appropriate pipe sections until t...

Page 22: ...ps Typical Roof Support Application Typical Ceiling Support Application FP1184 Fig 44 Venting supports Min 2 610 mm FP1185 Fig 45 Minimum termination to roof clearance TWL101a Twist Lock Pipe 2 8 99 d...

Page 23: ...ination Kit Starter Kit Model 7TDVSKV Vertical Venting for 7TDVSKV A order 1 12 to 6 12 roof pitch for 7TDVSKV B order 7 12 to 12 12 roof pitch for 7TDVSKV F order at roof Starter Kit for Below Grade...

Page 24: ...three times with a non ammonia household cleaner and warm water gas replace glass cleaner is recommend ed After the initial cleaning process the glass should be cleaned two or three times during each...

Page 25: ...logs from packaging As with all plastics these are not toys and should be kept away from children and infants Installation of Logs Log Identi cation Chart Logs Part ID Top Right Log 20012595 B162 Lef...

Page 26: ...Figure 54 Locator Pins LG462 Figure 53 Rear Log 3 Place rear log The rear log sits in the rebox at an angle toward the left over the rear log bracket and the left side of the burner Fig 50 Set the lo...

Page 27: ...the back Match the two holes on the bottom of the log with the two pins on the top of the front log Refer to Figure 53 for pin loca tions Set the log and lay it into the rear log Fig 55 7 Place the t...

Page 28: ...tions below Figs 57 58 If any of the ames appear abnormal call a service person Inspecting the Venting System This appliance venting system is designed and con structed to develop a positive ow adequa...

Page 29: ...area for gas Be sure to smell next to the oor because some gas is heavier than air and will settle on the oor WHAT TO DO IF YOU SMELL GAS Do not try to light any replace Do not touch any electric swi...

Page 30: ...tion FP297A Warning If you do not follow these instructions exactly a re or explosion may result causing property damage personal injury and loss of life Lighting Instructions Turning Off the Gas to t...

Page 31: ...not supplied must be used to conduct this test 3 Pilot burning no gas to A Wall switch or wires Check wall switch and wires for proper connections main burner defective Jumper wire accross terminals a...

Page 32: ...ame recti cation sensor is securely connected to the terminal labeled S on the control module Fig 60 Make sure the orange and white leads from the module are securely connected to the terminals labele...

Page 33: ...body Fig 62 Make certain the pilot ame is in contact with the ame recti cation sensor on the pilot assembly This valve is equipped with a pilot ame adjustment screw Fig 62 If the pilot ame is too sma...

Page 34: ...on the replace Ensure there is no blockage in the pilot line Sensor Safety Protection for Flame Sensor Error Code 4 beeps every one second Description of Fault Warn users the pilot ame sensor detects...

Page 35: ...ating the transmitter will now work with the re ceiver valve If the switch continues in the REMOTE position the transmitter will now control the main valve ame modulation level and fan control 7 If th...

Page 36: ...ove cover on the backside of the transmitter Install 3 AAA batteries as shown and reattach cover 2 Once steps 1 3 in OPERATION are completed receiver valve and transmitter are now ready Press any butt...

Page 37: ...g is above room temperature on the transmitter does the main valve and fan turn on If the setting is below room temperature on the transmitter does the main valve and fan turn off Turn pilotstat knob...

Page 38: ...it period Cycle switch once and leave in remote Press any key on transmit ter for recognition operation Local Path Move switch from local to remote Press any key on transmitter Move switch back to loc...

Page 39: ...ulator assembly to the valve using the new screws E supplied with the kit Tighten the screws securely Ref torque 25 in lb Fig 68 FC107 SIT820 valve conversion 10 03 A B C OFF P I L O T O N FC107 Fig 6...

Page 40: ...sion Instructions Honeywell Comfort Control Valve ONLY WARNING The conversion must only be undertaken by a quali ed certi ed gas ap pliance installer Installation Precautions Before proceeding turn co...

Page 41: ...ame 6 Follow procedure on rating plate to light the pilot Check for leaks 7 Turn main burner on and check for leaks 8 Install logs Refer to Page 26 for proper log place ment Installation complete Con...

Page 42: ...sembly thermopile millivolt gas valve Most of these components may require only an oc casional checkup and cleaning and some may require adjustment If repair is necessary it should be per formed by a...

Page 43: ...37 35a b 52 21c 12322 DVB4136 parts 7 07 5 3 1d 1e 2 15a b 19 18 20 45 47 49 53 6 1f 64 65 CFM Corporation reserves the right to make changes in design materials speci cations prices and discontinue...

Page 44: ...000062 20 24 Wire Harness 8 Pin 8 Wire IN IP 20012258 21a Pilot Assembly RN Nat 10002264 Pilot Assembly RP LP 10002265 21b Pilot Assembly RFN Nat 3 Way 20002266 Pilot Assembly RFP LP 3 Way 20002268 21...

Page 45: ...48 Flue Cover Gasket 10002233 49 Flue Plate Gasket 20011830 50 Flue Pipe Assembly 20011826 51 Gasket Plate Cover Flue Pipe 10002237 52 Plate Relief w Gasket Assy 10002429 53 Outer Collar Assembly 200...

Page 46: ...place base lining up mounting holes with screw studs Fasten fan speed control box with 10 24 hex nuts Option B The speed control can be installed in an electrical box at normal wall switch height for...

Page 47: ...ort 2 23 99 djt Rear Ceramic Panel Back of Firebox Burner Rear Log Support H102 Fig 82 Rear ceramic panel placement Decorative Bay Windows The bay window kit is available for the DVB4136 only Installa...

Page 48: ...the tabs on the hinges into the slots in the base pan front and secure with two 2 screws provided Fig 85 6 Close bottom louvre Installation complete 1 2 FP1601 Louvre removal 12 05 Louvre Glass Panel...

Page 49: ...to cool completely before beginning installation 1 Remove bottom louvre Find the female terminals on the unused red and black colored wires on the wire harness located behind the louvre opening 2 Conn...

Page 50: ...50 DVB4136 Direct Vent Gas Fireplace 20012322...

Page 51: ...upon inspection the damage is found to be the fault of the manufacturer repairs will be authorized at no charge to the customer parts and or labor Any part and or component replaced under the provisio...

Page 52: ...ciency Fan OFF Fan ON AFUE DVB4136RN 62 4 82 83 64 DVB4136RP 62 4 83 84 64 DVB4136IN 62 4 82 83 64 DVB4136IP 62 4 83 84 64 DVB4136RFN 62 4 82 83 64 DVB4136RFP 62 4 83 84 64 2695 Meadowvale Blvd Missis...