background image

1.

Signals  were  transmitted  by  laser  through  optical  fiber.  The  laser  meets  the 

requirement of class I, no harm with normal operation. Do not look directly into the 

fiber port and the end of the optical fiber terminator. 

2.

Dust plugs need to be installed when optical connectors and optical modules are 

not in use. Dust caps need to be installed when optical fibers are not in use. 

3.

The bending radius of optical fiber should be greater than 20 times the diameter of 

the optical fiber. In general, the bending radius should be equal to or greater than 

40mm. 

1.

When using a switch, the voltage can only be input from V1+ and V1-, V1+ connects 

to live wire L, and V1- to neutral wire N. Do not connect from V2+, V2-; pay attention 

to safety and prevent electric shock. 

2.

Power-on  operation:  First  connect  the  power  cord  to  the  power  terminal  of  the 

device according to the definition shown in the figure above, and then power on. 

3.

Power-off operation: first unplug the power plug, and then remove the power cord. 

        Warning 

 

 
 
 
 
 
 
 
 
 
 

 

Power input 

Before connecting the power cord, make sure that the ground is connected. Do 

connect the power cord to the power terminal of the device according to the definition. 

 

 

 

 

 

 

 

 

 

Notes 

 

 

 

 

 

 

 

 

 

 

 

MIEN2206-2F

 

MIEN2208

 

Switch properties

 

Bandwidth

 

1.6G

 

Cache size

 

768Kbit

 

MAC table

 

2K

 

Interface

 

100M fiber port

 

2*100Base-FX

 

SC/FC/ST connectors are available

 

100M copper port

 

4*10 /100Base-TX RJ45 ports 

8*10 /100Base-TX RJ45 ports

 

Full-duplex/half-duplex adaptive, supports MDI/MDI-X adaptive

 

Power supply 

 

Consumption

 

2.6W@24V(MAX)

 

1.8W@24V(MAX)

 

DC power input

 

DC9-60V

 

Supports dual power supply redundancy and reverse connection protection 

AC power input

 

AC85~264V (frequency: 47~63Hz) or DC110~370V

 

Mechanical

 

Size

 

140mm×35mm×100mm

L×W×H

(not include din-rail)

 

Installation 

35mm standard din-rail

 

Heat

 

Aluminum alloy single-rib chassis surface scattered

 

IP protection

 

IP40

 

Weight

 

About 0.54kg

 

Working environment

 

Working Temp.

 

-40

~+85

 

Storage Temp.

 

-40

~+85

 

Humidity 

5%~95%

No condensation)

 

 

Specifications

 