Usually, there is the grounding bar on the cabinet and we can connect the
grounding cable of the device to the grounding bar.
�
Please use the grounding cable carried by the switch.
The steps of installing the grounding cable are as follows:
Step 1:
Remove the grounding screws on the chassis of the device.
Step 2:
Bind the wiring terminal of the grounding wire carried by the switch to the
grounding screws of the chassis.
Step 3:
Install the grounding screws with the grounding wire to the grounding holes and
tighten it.
Step 4:
Use the same method to install the other side of the ground cable to the grounding
terminal of the cabinet.
F
F
F
F
I G U R E
I G U R E
I G U R E
I G U R E
3
3
3
3
9
9
9
9 C
C
C
C
O N N E C T
O N N E C T
O N N E C T
O N N E C T T H E
T H E
T H E
T H E G R O U N D
G R O U N D
G R O U N D
G R O U N D W I R E
W I R E
W I R E
W I R E
�
If there is no appropriate grounding point on the cabinet, we also can connect
the grounding wire of the switch to other grounding bar of the installation
place.
�
Fire hose and lightning rod grounding of the building are not the proper
grounding location; the grounding wire of the switch should be connected to