www.maintronic.de [email protected]
9
6.
Operation via buttons
6.1
Device button
1
6.3 Functions push button operation:
Max-Level 100%
- When doub
-
le-clicking 100%, the brightness
jumps to maximum 100%. The
previous dimming level will not
be overwritten and will be reacti
-
vated the next time it is switched
on. If the brightness is subse
-
quently „lowered“ again with a
single keystroke, the previous
output brightness is restored.
So you can quickly switch from
a low level to full brightness and
back.
Last Memory Level
- The last set
brightness level is saved and will
be recalled at next power up.
6.2
Push button input
Universal voltage input
It is possible to operate and program the device via
the device button.
NOTE - Operation with the device button
is only possible within the first 60 minutes
after Power-On and will be deactivated
after 60 minutes.
The device is equipped with a push button input
(T), on which standard 230V AC buttons can be
connected. Both DC voltage (from 12V DC) or AC
voltage can be used on the push button input.
The mains voltage will be used as alternating volta
-
ge. No polarity has to be observed.
For DC voltage, the supply voltage of the DMX sig
-
nal side (-X2) can be used. It is absolutely necessary
to pay attention to the correct polarity. DC(+) must
be connected to terminal 6, DC(-) to terminal 5.