background image

 
 

 

 

Infrared heating lamp 

CALDO BELLO CB1, CB2, CB3, CB4 

 

 

 

INSTALLATION OF THE LAMP: 

ATTENTION! 
a. The lamp should be hung from above. It should not be supported on boxes, cages 

or  any  other  kind  of  object.  Neither  should  it  be  placed  on  the  ground  in  direct 
contact with the floor or with the animals.

 

b.   MAKE  SURE  THE  EL ECTRI C  POWER  CABL E  I S  A WAYS  OUT  OF   RE ACH  OF   THE 

L I VES TOCK.  

c.  Attention:  Please  ensur e  that  liqu id   does  not  come  in  contact  with  the 

heater or bu lb. 

Hook a chain or a cable on the eyelets on the back of the lamp: 

 

For chicks of hen, pheasant, duck, goose, bantam, turkey, quail, grey partridge and red partridge: hang the 
lamp at ca. 50 cm. from the ground up to 20 days from their birth; 

 

For chicks of  Ratite  (Ostrich,  Emu and  Rhea):  hang the  lamp at ca. 70 cm. from the ground  up to 20 days 
from their birth. 

 

ELECTRIC CONNECTION: 

BEFORE  CONNECTING  THE  APPLIANCE  TO  THE  ELECTRICITY  LINE  AND/OR  SWITCHING  IT  ON  READ  THE 
FOLLOWING CAREFULLY. THE MAKER DOES NOT TAKE ANY RESPONSIBILITY FOR INJURIES OR FOR DAMAGES 
THAT  MIGHT  OCCUR  TO  PEOPLE  AND  TO  THE  HEAT  LAMP  DUE  TO  LACK  OF  ATTENTION  TO  THE  FOLLOWING 
PROCEDURE.  MAKE  SURE  THAT  THE  VOLTAGE  IS  THE  SAME  OF  THE  ONE  WRITTEN  ON  THE  TECHNICAL 
INFORMATION  PLATE. IF THE ELECTRIC INFORMATION  PLATE  STATES A DIFFERENT  VOLTAGE  CONTACT YOUR 
DEALER.  DO  NOT  CONNECT  THE  POWER  CORD  TO  THE  ELECTRICITY  LINE  AND  DO  NOT  SWITCH  ON  THE 
APPLIANCE ON. MAKE SURE THAT THE PLUG OF THE HEAT LAMP YOU USE TO CONNECT TO THE ELECTRICITY 
LINE IS SUITABLE TO THE SOCKET YOU WANT TO USE; IF IT IS NOT SO CONTACT YOUR DEALER. DO NOT TRY 
TO  CHANGE  THE  PLUG  BY  YOURSELF,  OTHERWISE  THE  GUARANTEE  CERTIFICATE  IS  NOT  VALID  ANYMORE. 
SWITCHING ON OF THE APPLIANCE: AFTER HAVING CHECKED ALL THE DIRECTIONS LISTED ABOVE AND ONLY 
IN THE CASE THAT NO FURTHER INTERVENTIONS ARE NECESSARY PUT THE PLUG IN THE SOCKET to SWITCH 
ON THE APPLIANCE. To switch off the appliance disconnect the plug from the socket. 

PLEASE  ENSURE  THE  PLUG  IS  REMOVED  FROM  THE  ELECTRICAL  SOCKET  BEFORE 

ATTEMPTING ANY MAINTAINANCE/CLEANING ON THE HEAT LAMP. 

 

HOW TO ADJUST TO THE REQUIRED TEMPERATURE: 

Place  a  thermometer  (optional  accessory  not  provided  with  the  lamp)  below  the  lamp  and  adjust  the 
temperature with the knob on the upper part of the lamp. Rotate it clockwise to increase it and anti-clockwise 
to  decrease  it  until  you  reach  the  required  temperature. 

Once  you  finish  the  adjustment:

  Remove  the 

thermometer, place it in the proper case and keep it carefully for next use.

 

 

T E C H N I C A L  F E AT U R E S :       C A L D O   B E L L O   H E AT  L A M P

 

E L E C T R I C   F E AT U R E S :     B R I T I S H   P L U G   2 P O L E + E   –  1 3  A .   F U S E     –     N O R M S C O D E :   BS 1363A/95

 

T E N S I O N :     2 3 0   Va c   + 1 0 / - 15 %       ;       F R E Q U E N C Y:     H z .   5 0  ±0 , 5 %

 

TO TA L  P OW E R   C B 1  A N D   C B 2 :   0 . 2 5 KW   –  C B 3  A N D   C B 4 :   0. 5 KW

 

DO  NOT  DISASSEMBLE  THE  BUFFLE  AND  THE  PROTECTION  NET.  DO  NOT  REMOVE  OR 

TOUCH THE INFRARED  LAMP WITH  YOUR  HANDS.  THERE  IS  GREAT DANGER OF  BURN  AND 

DANGER  OF  BREAKING  THE  HEATING  ELEMENT!    ATTENTION:  IT  IS  AN  HALOGEN  LAMP  AT 
HIGH  TEMPERATURE  COVERED  WITH  A  SPECIAL  INFRARED  FILTER.  DO  NOT  IMMERSE  THE 

STRUCTURE OR THE LAMP INTO WATER, DO NOT WET IT AND DO NOT WASH IT. CLEAN DRY 
USING A BRUSH OR COMPRESSED-AIR.    

 

HOW TO CHANGE THE LAMP: 

Call the technical assistance. Together with the heating bulb you will receive the instructions to change it. 

 

 

The linked  image cannot  be display ed.   The file may   hav e been  mov ed, renamed, or  deleted. V erify   that the link  points to the  correct file  and location.