5.0 Clearances

8

© Baxi Heating UK Ltd 2009

200mm Min

780mm

450mm

200mm Min

5mm Min

5mm Min

450mm Min

For Servicing

Purposes

In Operation

20mm/5mm Min

see *NOTE:

5.1

For your Safety

1. This appliance must have been installed in accordance
with the manufacturer’s instructions and the regulations
in force.

2. Any modification that may interfere with the normal
operation of the appliance without express written
permission from the manufacturer or his agent could
invalidate the appliance warranty. In GB this could also
infringe the Gas Safety (Installation and Use) Regulations.

3. Your boiler must not be operated without the casing
correctly fitted.

4. Do not interfere with any sealed components on this
boiler.

5. Take note of any warning labels on your boiler.

6. Your boiler should have the following minimum
clearances for Safety and Maintenance 
(Fig. 34):-

Top

- 200mm

Bottom

- 200mm

Left side

- 5mm

Right Side

- 5mm

Front

- 5mm (In Operation)
- 450mm (For Servicing)

*NOTE:

The boiler can be operated with a clearance

of 5mm at the right. This is also sufficient for routine
maintenance. However a clearance of 20mm is
required if it is necessary to remove the secondary
heat exchanger. This should be considered when
siting the appliance and in the event of any
subsequent alteration in the area of installation.

7. If your boiler is installed in a compartment, do not use
it for storage purposes. Do not obstruct any purpose
provided ventilation openings.

8. Flammable materials must not be stored in close
proximity to your boiler.

9. Avoid skin contact when your boiler is in operation, as
some surfaces may get hot e.g. pipework.

10. Ensure that the flue terminal, outside the house,
does not become damaged or obstructed, particularly
by foliage.

11. It is important that the condensate drain system is
not blocked, modified or damaged in any way as this
would affect the operation of your boiler. Your installer
should have insulated any exposed pipework.

GB

- Heating Industry definition meaning England, Scotland,

Wales, Northern Ireland, Isle of Man and the Channel Isles

Summary of Contents for Combi 30 HE

Page 1: ...Baxi Heating UK Ltd 2009 User s Guide and Important Warranty Information Combi 30 HE Please keep these instructions in a safe place If you move house please hand them over to the next occupier...

Page 2: ...Heating and Hotwater Industry Council For more information visit www centralheating co uk Baxi Heating UK Ltd 2009 All rights reserved No part of this publication may be reproduced or transmitted in a...

Page 3: ...illuminate when there is a demand for heat to the boiler Central Heating System Pressure The normal operating water pressure is between 1 and 2 0 bar If the pressure exceeds 3 bar the safety pressure...

Page 4: ...electricity to the boiler is switched on Reset Power On Indicator Boiler On Indicator Burner On Indicator Boiler operating satisfactorily bar 0 1 2 3 4 Is the Central Heating System Pressure needle in...

Page 5: ...itted set high enough 15 10 5 20 2 5 15 10 5 20 2 5 Turn Room Thermostat to maximum setting typical example shown If you don t know what you need to do to get the boiler to light or need help with the...

Page 6: ...operate for 1 minute in every 24 hours to prevent sticking 3 5 Safety Thermostat 1 Your Baxi Combi HE is fitted with an additional safety devices which shut down the boiler in the event of the system...

Page 7: ...refully open the second tap 6 When the needle on the gauge is indicating 1 or more turn both taps off 7 Disconnect the metal braided hose from the taps a small amount of water may be present and remov...

Page 8: ...eration 450mm For Servicing NOTE The boiler can be operated with a clearance of 5mm at the right This is also sufficient for routine maintenance However a clearance of 20mm is required if it is necess...

Page 9: ...system the gas and electricity must be left on and the appliance set in the central heating mode 3 The boiler incorporates an integral pump protection feature which continually monitors the time since...

Page 10: ...r gaseous fuels Type test for purpose of Regulation 5 certified by Notified Body 0051 Product Production certified by Notified Bodies 0051 0086 For GB IE only 7 2 Benchmark Commissioning Checklist 1 P...

Page 11: ...t not be used until the fault has been corrected by a competent person Warning Gas Tap Heating Flow and Heating Return Isolating Valves Fig 10 In an Emergency If a water or gas leak occurs or is suspe...

Page 12: ...er visit or for any general advice that you may need Our contact centre is open Monday to Friday 8am 6pm weekends and Bank Holidays 8 30am 2pm excluding Christmas Day and New Years Day When calling he...

Reviews: