8.0 Emergency

11

© Baxi Heating UK Ltd 2009

If you smell gas

Turn off the gas supply at the meter and call your gas
supplier immediately.

It is possible to isolate the boiler at

the isolating valve (Fig. 10).

In GB, Transco operate a 24 hour emergency service and
the telephone number will be listed in your telephone
directory.

Faulty boiler

If it is known or suspected that a fault exists 
on the boiler, it must not be used until the fault 
has been corrected by a competent person.

Warning !

Gas Tap

Heating Flow and

Heating Return Isolating

Valves

Fig. 10

In an Emergency

If a water or gas leak occurs or is suspected, the boiler can
be isolated at the inlet valves as follows;

1. Using a suitable open ended spanner, turn the square
nut on the gas tap through 90° (

1

/

4

turn) to isolate the gas

supply at the boiler (Fig. 10).

2. The water isolating valves are positioned under the
boiler and can be closed by turning their taps to the right
towards the wall (Fig. 10).

3. Call your Installer or Service Engineer as soon as
possible.

Summary of Contents for Combi 30 HE

Page 1: ...Baxi Heating UK Ltd 2009 User s Guide and Important Warranty Information Combi 30 HE Please keep these instructions in a safe place If you move house please hand them over to the next occupier...

Page 2: ...Heating and Hotwater Industry Council For more information visit www centralheating co uk Baxi Heating UK Ltd 2009 All rights reserved No part of this publication may be reproduced or transmitted in a...

Page 3: ...illuminate when there is a demand for heat to the boiler Central Heating System Pressure The normal operating water pressure is between 1 and 2 0 bar If the pressure exceeds 3 bar the safety pressure...

Page 4: ...electricity to the boiler is switched on Reset Power On Indicator Boiler On Indicator Burner On Indicator Boiler operating satisfactorily bar 0 1 2 3 4 Is the Central Heating System Pressure needle in...

Page 5: ...itted set high enough 15 10 5 20 2 5 15 10 5 20 2 5 Turn Room Thermostat to maximum setting typical example shown If you don t know what you need to do to get the boiler to light or need help with the...

Page 6: ...operate for 1 minute in every 24 hours to prevent sticking 3 5 Safety Thermostat 1 Your Baxi Combi HE is fitted with an additional safety devices which shut down the boiler in the event of the system...

Page 7: ...refully open the second tap 6 When the needle on the gauge is indicating 1 or more turn both taps off 7 Disconnect the metal braided hose from the taps a small amount of water may be present and remov...

Page 8: ...eration 450mm For Servicing NOTE The boiler can be operated with a clearance of 5mm at the right This is also sufficient for routine maintenance However a clearance of 20mm is required if it is necess...

Page 9: ...system the gas and electricity must be left on and the appliance set in the central heating mode 3 The boiler incorporates an integral pump protection feature which continually monitors the time since...

Page 10: ...r gaseous fuels Type test for purpose of Regulation 5 certified by Notified Body 0051 Product Production certified by Notified Bodies 0051 0086 For GB IE only 7 2 Benchmark Commissioning Checklist 1 P...

Page 11: ...t not be used until the fault has been corrected by a competent person Warning Gas Tap Heating Flow and Heating Return Isolating Valves Fig 10 In an Emergency If a water or gas leak occurs or is suspe...

Page 12: ...er visit or for any general advice that you may need Our contact centre is open Monday to Friday 8am 6pm weekends and Bank Holidays 8 30am 2pm excluding Christmas Day and New Years Day When calling he...

Reviews: