INSTRUCTION MANUAL FOR DISHWASHERS
MDI TT28-26 - 02
Page 5 of 20
UK
Characteristic
FROM
TO
Hardness
French degrees
f
5
10
German degrees
°dH
4
7’5
British degrees
°e
5
9,5
Parts per million
ppm
70
140
Mineral
residues
Maximum
mg/l
300/400
Free drain
1.5
CONNECTION TO THE DRAIN LINE
•
The drain line must be made up of a free water trap of a size
proportionate to the delivery of the drain pipe supplied with the machine.
The pipe must be able to reach the water trap without being pulled,
squeezed, bent, crushed, pressed or forced in any way
.
•
The tank empties by gravity, so the drain must be at a
lower level than the
base of the machine.
With discharge pump (available
on request)
•
If the drain is not at a lower level than the base of the machine, you can use
the version equipped with a discharge pump (available on request).
•
In this case the maximum drain height is 1 m.
•
Always check that the drain works properly and that it is not clogged.
•
All other solutions must be previously agreed upon and approved by the
manufacturer.