WIRING DIAGRAM

WS 170 KR

Version: 2019-08-30 - MAICO VENTILATOREN, www.maico-fans.com - We are not responsible for mistakes or printing errors and retain the
right to make technical modifications without giving prior notice

Page 7

WS 170 ventilation unit with hygrostat and RLS 1 WR or RLS D1 WR room air con-
trol

W 1

G

N

Y

E

B

U

B

N

P E

N

L

W 4

A

B

W 2

W 2 '

I I

I

I I I

B 1

8

9
10

C O 2

B D E
O N / O F F

6

7

J u m p e r

1

A 2

2 3

1

r F >

r . F .

C O 2

A - WS 170 electronic slide-in module
A2 - Control circuit board: Jumper 8 bridged and jumper 10 (CO2) = open (= factory setting)
B - RLS D1 WR room air control
B1 - RLS 1 WR rH room air control HY 5 or HY 5 I hygrostat
W1 - 230 V AC connection cable
W2, W2´ - Control cable for room air control
W4 - Connection cable for external hygrostats (to be supplied by the customer). Connection to A2 control circuit board
at CO2 terminals
When connecting a hygrostat with potential-free contact for demand-driven removal of moisture, the hygrostat must
have a potential-free switching output.
The hygrostat always switches the ventilation unit to ventilation level 3 if the set humidity value is exceeded (poten-
tial-free contact in hygrostat closes).
If the humidity in the room drops, the ventilation unit switches back to the previously selected ventilation level.
If you switch manually from ventilation level 3 to level 2 or 1, this deactivates the automatic function of the hygrostat
temporarily. This is then switched back to active if the level drops below the hygrostat set point once.
Connect the hygrostat to terminal "CO2".
Jumper 10 on the A2 control circuit board must be open.
Set the switching point at the hygrostat manually.
Never connect a hygrostat and a CO2 sensor/VOC sensor at the same time.

Summary of Contents for WS 170 KL

Page 1: ...L 1 N N e t z Z u l u f t N L 1 L 1 N L 1 L 1 N 1 2 3 4 5 6 7 8 9 1 0 CO2 BDE On Off Temp WH RD YE BU WH RD YE BU GNYE BU BN BN BU GNYE BN GNYE BU WH BU A2 0 10V BK T y p M1 J u m p e r a n z e i g e B e t r i e b s k1 GND 0 10V J1 W5 W3 W4 A1 S1 A3 0 10V M2 ABL ZUL 24V G N Y E B U B N PE N L W1 L L L N N L N N L L L L 3 N N N N 4 PE PE PE PE 5 B N B N B U B K G N Y E 2 1 X1 S B U B U S G N Y E KL...

Page 2: ...ntilation level 3 Jumper settings J 1 3 Unit type 000 WS 170 J 4 5 Frost protection temperature J 6 No function J 7 Jumper 7 open Ventilation level 3 is reset after an hour J 8 RLS 1 WR or RLS D1 WR room air control active Leave factory setting J8 must be bridged J 9 Jumper 9 open The ventilation unit can be switched off at the room air control Jumper 9 bridged RLS 1 WR Switch off function blocked...

Page 3: ...S2 BN GY YE GN PK WH B1 II I III LD3 LD2 LD1 S1 S2 B2 BN GY YE GN PK WH W2 BN WH PK GY GN YE A WS 170 electronic slide in module A2 Control circuit board Jumper 8 bridged factory setting B1 1 RLS 1 WR room air control B2 2 RLS 1 WR room air control W1 230 V AC connection cable W2 Control cable for room air control V Distributor supplied by the customer You can connect up to 5 RLS 1 WR room air con...

Page 4: ...ions without giving prior notice Page 4 WS 170 ventilation unit with RLS D1 WR room air control 8 9 10 CO2 BDE ON OFF 6 7 Jumper 1 A2 A W1 W2 W H B N B G N Y E B U B N PE N L A WS 170 electronic slide in module A2 Control circuit board Jumper 8 bridged factory setting B RLS D1 WR room air control W1 230 V AC connection cable W2 Control cable for room air control shielded control cable ...

Page 5: ...g B RLS D1 WR room air control B1 RLS 1 WR room air control H1 Display element e g glow lamp to be supplied by the customer W1 230 V AC connection cable W2 W2 Control cable for room air control W3 Cable for an external operating display to be supplied by the customer The connection on A2 control circuit board is done at the Operating display terminals An operating display lamp contactor etc can be...

Page 6: ...Jumper 8 bridged factory setting Jumper 10 bridged sensor is detected B RLS D1 WR room air control B1 RLS 1 WR room air control CO2 SKD CO2 sensor VOC EAQ 10 2 air quality controller W1 230 V AC connection cable W2 W2 Control cable for room air control W4 Connection cable for external CO2 sensor and or VOC sensor provided by customer Connection to A2 provid ed by customer at CO2 and OT terminals S...

Page 7: ...upplied by the customer Connection to A2 control circuit board at CO2 terminals When connecting a hygrostat with potential free contact for demand driven removal of moisture the hygrostat must have a potential free switching output The hygrostat always switches the ventilation unit to ventilation level 3 if the set humidity value is exceeded poten tial free contact in hygrostat closes If the humid...

Page 8: ...onic slide in module A2 Control circuit board Jumper 8 bridged factory setting B RLS D1 WR room air control B1 RLS 1 WR room air control P Differential pressure controller with potential free relay contact k provided by customer k Switching output potential free relay contact W5 Connection cable for differential pressure controller provided by customer If there is negative pressure in the room the...

Page 9: ...tory setting B RLS D1 WR room air control B1 RLS 1 WR room air control GW1 Gateway frost protection heat register GW2 Gateway bypass shutter only WS 170 bypass unit T1 Supply air temperature sensor in supply air channel provided by customer W1 230 V AC connection cable W2 W2 Control cable for room air control W6 Connection cable of supply air temperature sensor Connection on GW1 circuit board to K...

Reviews: