background image

 

5

Ventilation levels: 

Humidity pro-

tection, ventilation level 1 to 3 and 

intermittent ventilation. Can be set with 

manual, ECO mode supply air or ECO 

mode exhaust air operating modes.

Room temperature: 

Actual tempe-

rature = current room temperature. 

Setpoint temperature can be set with 

optional supplementary heating.

Season: 

Summer or winter opera-

tion The season has to be changed 

manually.

1.2 Main menu settings

For basic system settings. Depending on au-

thorisation (installer, owner, tenant), different 

system parameters can be set.

1.3 Retrieve main menu

Here current system values such as tempe-

rature and humidity measurements, system 

statuses or fault messages can be queried.

2 Mounting

i

 

For applicable safety regulations and 

further information 

 Installation, com-

missioning and maintenance instruc-

tions for ventilation unit.

2.1 

Qualifications of specialist installer

Only a 

trained electrician

 is permitted to 

work on the electrics. You are considered a 

trained electrician if your specialist training 

and experience 

 

means that you are familiar with the relevant 

standards and guidelines

 

enables you to correctly and safely 

undertake the electrical connections in 

accordance with the wiring diagram in the 

installation instructions

 

enables you to recognise and avoid risks 

and hazards associated with electricity and

 

you are able to recognise and avoid risks 

resulting from incorrect installations and 

settings and the resultant hazards.

2.2 Scope of delivery

Touchscreen operating unit, mounting plate, con-

nector plug and these installation instructions.

2.3 Intended use

With the comfort control unit, the user can 

operate the ventilation unit and undertake 

individual settings on it. Numerous configu

-

ration options are available to the specialist 

installer in the protected installer area of the 

touchscreen operating unit.

Read the safety instructions in the instal-

lation instructions for the ventilation unit 

before connecting the touchscreen opera- 

ting unit

 

to the ventilation unit. Follow the 

instructions.

2.4 Safety instructions

Danger from electric shock: 

Before removing the front cover, 

shut down all supply circuits (de-

activate the mains fuse) and se-

cure so they cannot be switched 

back on. Attach warning sign in 

clearly visible place. 

Danger of injury when fans 

are running:

 Before removing 

the front cover, wait until both 

fans have stopped.

Danger of burning from hot 

housing parts on units with 

PTC heat register:

 After re-

moving the front cover, do not 

touch the heat register. First wait 

until the heat register and the 

housing parts have cooled off. 

Store packaging material out of 

the reach of children

 

 Risk of 

suffocation if swallowed.

Summary of Contents for RLS T1 WS

Page 1: ...stensperre aktiv 13 Aktueller Hinweis 14 Aktuelle Störmeldung Erscheint nur wenn der Status aktiviert ist oder eine Meldung anliegt 1 1 Schnellauswahlmenüs Betriebsarten Auto Zeit und Auto Sensor Manuell Eco Betrieb Zuluft Eco Betrieb Abluft und Aus Lüftungsstufen Feuchteschutz Lüftungsstufe 1 bis 3 und Stoßlüftung Einstellung bei Betriebsart Manuell Eco Betrieb Zuluft oder Eco Betrieb Abluft Raum...

Page 2: ...en Fachinstallateur stehen im geschütz ten Installateurbereich des Touchscreen BDE s vielfältige Konfigurationsmöglichkeiten zur Verfügung Lesen Sie zuerst die Sicherheitshinweise der Installationsanleitung des Lüftungsge rätes bevor Sie das Touchscreen BDE mit dem Lüftungsgerät verbinden Folgen Sie den Anweisungen 2 4 Sicherheitshinweise Gefahr durch Stromschlag Vor dem Abnehmen der Frontabdeckun...

Page 3: ...n Innerhalb des Lüf tungsgerätes für genügend lange Anschluss leitungen sorgen ACHTUNG Kurzschlussgefahr Gerätebeschädigung bei Wassereintritt in Elektronikfach Für korrekte dichte Leitungszuführung durch die Kabeldurchführung sorgen 3 Kabeldurchführung fachgerecht durch stoßen 4 Anschlussleitung durch Kabeldurchführung in das Lüftungsgerät füh ren Dichtigkeit prüfen und sicherstellen i Anschlussl...

Page 4: ...tion level 3 Current actual room temperature 4 Season currently set 5 Main menu Settings 6 Main menu Query 7 Filter change display 8 Status display summer bypass open only bypass devices 9 Status display frost protection active 10 Status display supplementary heating on 11 Logout field 12 Key lock active 13 Current note 14 Current fault message Only appears if the status is activated or a message ...

Page 5: ...ructions enables you to recognise and avoid risks and hazards associated with electricity and you are able to recognise and avoid risks resulting from incorrect installations and settings and the resultant hazards 2 2 Scope of delivery Touchscreen operating unit mounting plate con nector plug and these installation instructions 2 3 Intended use With the comfort control unit the user can operate th...

Page 6: ...ics compartment Hang slide in module in fitting studs if present NOTICE If the connection cables are too short the electronic slide in module cannot be fully pulled out fitted Ensure connection cables of a sufficient length inside the ventilation unit NOTICE Danger of short circuits damage to unit should water enter the electronics com partment Ensure a correct sealed line feedthrough through the ...

Page 7: ...480 x 272 pixels 4 3 Rated voltage 12 V Power frequency 50 Hz 60 Hz NTC room temperature sensor 20 C to 50 C 4 Disposal Dispose of packaging material according to local regulations Acknowledgements Maico Elektroapparate Fabrik GmbH Translation of the original German instructions We cannot be held responsible for mistakes or prin ting errors and retain the right to make technical modifications with...

Page 8: ...r sort ant ECO et Arrêt Niveaux de ventilation protection contre l humidité niveaux de ventila tion 1 à 3 et ventilation par à coups Réglages en mode de fonctionnement Manuel mode Air entrant ECO ou mode Air sortant ECO Température ambiante température réelle température ambiante actuelle Température de consigne réglable en cas de réchauffage optionnel Saison mode Été ou mode Hiver La commutation ...

Page 9: ...le niveau Installateur pro tégé de l unité de commande à écran tactile l installateur spécialisé dispose d un grand nombre de possibilités de configuration Veuillez lire en premier lieu les consignes de sécurité de la notice d installation de l appareil de ventilation avant de raccor der l unité de commande à écran tactile à l appareil de ventilation Suivez les instruc tions 2 4 Consignes de sécur...

Page 10: ...er le s cache s de protection Notice d installation de l appareil de ventilation 2 Soulever le module électronique et le retirer du compartiment électronique Accrocher le module d insertion dans les tétons de suspension si présents ATTENTION Le module électronique ne peut pas être complètement sorti accroché si les câbles de raccordement sont trop courts À l inté rieur de l appareil de ventilation...

Page 11: ...nctions avec l unité de commande à écran tactile 2 6 Remplacer l unité de commande Démontage étapes à Montage étapes à 3 Caractéristiques techniques Dimensions lxhxp 127 x 93 x 22 mm Type de montage Montage apparent Écran couleur TFT Écran tactile Résolution diagonale 480 x 272 pixels 4 3 Tension de service 12 V Fréquence du secteur 50 Hz 60 Hz Sonde de température am biante NTC 20 C à 50 C 4 Élim...

Page 12: ...0185 1226 0000_09 17_DSW Maico Elektroapparate Fabrik GmbH Steinbeisstr 20 78056 Villingen Schwenningen Deutschland Service 49 7720 694 0 technik maico de ...