5 Technical data
26
Ventilation solution for a 3-room flat with
PPB 30
K
ventilation units for the bathroom and
PP 45
ventilation units for living spaces. The
PPB 30 K
ventilates and extracts air from the bathroom, at
the same time, with balanced operation. A
PPB
30 K
fan ventilates the room with air which has
been pre-warmed in the heat exchanger. The
other
PPB 30 K
fan transfers the thermal energy
from the exhaust air to the heat exchanger during
air extraction. Every 60 seconds, the air direction
changes, thereby permitting a ventilation mode
with constant heat recovery. In case of high air
humidity, intensive ventilation can be activated via
a humidity sensor (automatically) or manually with
a button. Pure exhaust air mode is also possible
and here the two fans pump humidity out of the
room (no heat recovery).
5 Technical data
5.1 Requirements at the installation
site
• Ambient temperature - 15 °C to + 40 °C.
• Airstream temperature, max. 40 °C.
• Max. permissible humidity in installation room
PP 45
: 70 % /
PPB 30
: 90 % (at 20 °C).
• A level and solid wall surface is needed for wall
installations.
NOTICE: Conveyance of structure-borne
sound if core drill hole touches door/window
lintels or ring beams. Observe spacing
between core drill hole and door/window lin-
tels and ring beams.
• Exterior wall with sufficient load-bearing capa-
city (min. 200 kg/m³).
• For filter changes, ensure sufficient space to
work in front of the unit.
• Do not drill core drill hole for unit assembly and
do not drill fixing points on external and internal
covers in load-bearing components, such as in
the lintel or ring beam.
5.2 Technical data table
5.2.1 Technical data for PP 45
External diameter
DN 160
Wall sleeve
max. length
PP 45 RHK
: 500 mm
PP 45 RHL
: 800 mm
Wall thickness min.
Wall thickness max.
265 mm
490 or 790 mm
Rated voltage
230 V
Power frequency
50/60 Hz
Permissible ducting
lengths with wired
connection
From star point max.,
25 m per ventilation unit
For more technical data → rating plate.
5.2.2 Technical data for PPB 30
External diameter
DN 160
Wall sleeve
max. length
PP 45 RHK
: 500 mm
PP 45 RHL
: 800 mm
Wall thickness min.
Wall thickness max.
320 mm
790 mm
Degree of protection
IP X4
Rated voltage
230 V
Power frequency
50/60 Hz
Permissible ducting
lengths with wired
connection
From star point max.,
25 m per ventilation unit
For more technical data → rating plate.
Summary of Contents for PP 45 RHK
Page 3: ...Steuerungskonzept PP 45 3 Steuerungskonzept PP 45...
Page 4: ...Steuerungskonzept PPB 30 4 Steuerungskonzept PPB 30...
Page 22: ...PP 45 control concept 22 PP 45 control concept...
Page 23: ...PPB 30 control concept 23 PPB 30 control concept...
Page 41: ...Concept de commande PP 45 41 Concept de commande PP 45...
Page 42: ...Concept de commande PPB 30 42 Concept de commande PPB 30...
Page 59: ...Notizen...