7.1 Floor-mounted unit
¾
Set up heater fan in a vertical position.
Ensure that unit is level and stable.
7.2 Wall assembly
DANGER
Risk of injury and burns if
the unit is incorrectly wall
mounted.
¾
Only mount the unit on a wall
with adequate load-bearing
capacity and characteristics.
Note the weight of the unit.
¾
The appropriate mounting
material must be supplied by
the customer.
Prescribed minimum distances
¾
Use the wall bracket [3] supplied to mount
the unit.
¾
Make sure there is a flat surface to mount
the wall bracket on.
¾
Attach the wall bracket to the wall with
suitable fixing material ("S1", not included).
¾
Suspend the unit from the centre of the wall
bracket as shown in the diagram below
using the tubular stand.
¾
Make sure the unit is level. The control
panel must be easily accessible.
¾
Screw locking bolt "S2" fully into the wall
bracket to ensure that the unit is securely
bolted to the wall.
7.3 Electrical connection
●
The connecting cable for 400 V units is to
be supplied by the customer.
●
Fuse protection with 3-way circuit-breaker
is required for 400 V units:
– MHD 5 and MHD 9
with 16 A for each
phase
– MHD 15 and MHD 20
with 32 A for each
phase
¾
For the sake of security operate the unit
with a residual current device RCD (max.
30 mA).
.