1 Scope of delivery
5
ER-UPD with fire protection shut-off device
and ER-UPB with fire protection shut-off
device and fire protection cover
3 Metal shut-off shutter with release mechan-
ism
4 Soldered strut
5 Metal exhaust socket
5.
1
Metal connection socket DN 75/80 for second
room extraction ER-UPB
ER-ZR second room connection set
6 Protective grille
7 Filter mat, filter class G2
8 Adapter
9 Suction duct, ZR connection (not included in
ER-ZR set)
10 Plastic installation socket for second room
extraction
ER 60/100 fan insert
11
Fan insert
12
Electronic circuit boards
13
Housing floor seal
14
Sensor (H or F model)
15
Cover with central screw
16
Regulating plate for second room connec-
tion
17
Filter mat, filter class G2
18
Time strip
P
Production date
S1
Wiring diagram
S2
Rating plate
S3
TÜV sticker
ER-AS (special accessories)
Extraction socket for toilet seat air extraction DN
70
1 Scope of delivery
Depending on order, comprising:
•
Shell kit
: ER flush-mounted housing
•
Final assembly set
: Fan insert
•
Other accessories:
e.g. ER-AS for toilet seat
air extraction, spacer, wall and cover frames,
expanded rubber fitting etc.
Specialist installer qualifications
Installation may only be carried out by
trained
specialists
who have the necessary knowledge
and experience in
ventilation engineering
. The
unit must be connected in accordance with the
national technical approval.
Only a
qualified electrician
is permitted to work
on the electrics. You are deemed a qualified elec-
trician if you are familiar with the relevant stand-
ards and guidelines, can competently and safely
connect units to an electrical power supply in line
with the
and are able to
recognise and avoid risks and dangers associ-
ated with electricity on the basis of your technical
training and experience.
2 Intended use
These fans are used to extract air from interior
bathrooms and toilet rooms, storage rooms and
kitchens with an outside window.
If operated other than stated in DIN 18017-3, the
fans may also be used as standalone units (fitted
on the wall or ceiling) or to extract air from other
rooms (interior kitchen etc.).
The fans are only intended for domestic use and
similar purposes.
3 Safety instructions
3.1 General safety instructions
The unit must not be used in the following
situations under any circumstances:
DANGER Risk of combustion/fire from
flammable materials, liquids or gases in the
vicinity of the unit.
Do not place any flammable materials, liquids or
gases near the unit, which may ignite in the event
of heat or sparks and catch fire.
DANGER Explosion hazard due to gases
and dust.
Explosive gases and dust may ignite and cause
serious explosions or fire.
Never use unit in an explosive atmosphere (risk
of explosion).
DANGER Explosion hazard due to explos-
ive substances in the lab extraction units.
Explosive substances in lab extraction units may
ignite and cause serious explosions or fire.
Aggressive substances may damage the unit.
Never use unit in combination with a lab extrac-
tion unit (risk of explosion).