Maico 0157.0832 Installation And Operating Instructions Download Page 2

Maico Elektroapparate Fabrik GmbH

Steinbeisstr. 20 • D-78056 Villingen-Schwenningen • Service.: 0

7720 694 447

 • Fax: 

07720 694 239

 • e-mail: [email protected] • Internet: www.maico-ventilatoren.de 

3106 0000-181 Rev01

2

02.12_PH

1.   General

1.1   Application

The  radio  transmission  of  the  DS-RC  radio  switchs  takes 

place at the European harmonised frequency of 868.3 MHz. 

They are particularly suitable for areas where no repairs are 

required,  such  as  renovations,  retrofitting  of  electrical  sy-

stems or offices with mobile walls.

 

By pressing a button, con-

sumers can be switched wirelessly through receivers. 

The radio switchs must be assigned to the receivers.

 

There-

fore, refer to the receivers operating instructions. Every radio 

switch can control an indefinite number of receivers. 

 

Notes:

– The radio switchs function without batteries and are maintenance-free ! 

– Read through the operating instructions carefully before 

  putting the device into service.

1.3  Disposal of the device

The device must be disposed of in compliance with the laws and standards of the 

country in which it is operated!

2.   Safety

This device is only intended to be used for its stated application. Unauthorised conver-

sions, modifications or changes are not permissible! This device may not be used in  

conjunction with other devices whose operation could present a hazard to persons, 

animals or property.

The following must be observed:

•  Prevailing statutes, standards and regulations.

•  State-of-the-art technology at the time of installation.

•  The device’s operating instructions.

•  Operating instructions can only cite general stipulations. These are to be viewed in  

  the context of a specific system.

3.   Technical specifications

Note:

 

The strength of the radio signal between sender and receiver decreases with incre-

asing distance. The visually unobstructed range is about 30 m in passageways and 

100 m in open rooms. The range can be increased through the use of an repeater.

4.   Structure and description

The radio switchs are to be completed with the combination frames of the according 

switch programme. The combination frames have to be ordered separately! 

The following variations of radio switchs are available:

 

Retaining plate

DS-RC radio switch in Aura Design

Latches

DS-RC

O

  =  OFF 

I

  =  ON

 =  UP 

 =  DOWN

O

I

General data

Operating fequency

868.3 MHZ

Transmission power

10 mW

Modulation type  

(ASK Amplitude Shift Keying)

Cycles of operation

min. 50,000  

Operating temperature  

-25°C to +65°C in dry rooms

Relative humidity  

0% to 95 %

Protection type

IP20

Range in buildings

Masonry

20m (max. 3 walls)

Reinforced concrete 

10m (max. 1 wall/ceiling)

Drywall/wood

30m (max. 5 walls)

5.   Mounting and commissioning

1

2

3

4

5.1  Note on installation

•  Do not use in the open (only within closed rooms).

•  Before the installation on rough surfaces, a smooth surface has to be created.

  Unevenness may lead to radio switch’s malfunctions.

•  When installing, mind the required position of installation shown on the back of 

  the radio switch (O = top , 

I

 = bottom) 

(1)

.

•  Do NEVER install the radio switch within a metal body or in the immediate vicinity 

  of big metal objects. An installation near or on the ground is not recommendable.

5.2   Mounting

a)   Screws: 

   •  Retaining plates 

(4)

 shall be used as a template to mark the drill holes.

   •  Drill dowel holes of 5 mm.

   •  Fix the retaining plate with included screws. The latches of the retainin plate

     have to be positioned for their installation as shown under 

point 4

   •  Engage radio switch 

(2)

 and frame 

(3)

 on the retaining plate.

b)   Gluing:

   •  Engage radio switch 

(2)

 and frame 

(3)

 on the retaining plate 

(4)

.

   •  Use 

adhesive strips

 for the installation on flat, smooth surfaces (such as

      painted walls, tiles, furniture, wood, etc.) Glue the adhesive strip to both 

     the upper and lower recess on the indentation of the retaining plate.

   •  Use 

adhesive film

 for the installation on glass. Glue the adhesive film to the 

     inverse side of the retaining plate.

   •  Glue the assembled radio switch to the desired place.

5.3   Commissioning

•  Installation of the receiver (only by an electrician).

•  Assign radio switch to receiver.

6.   Troubleshooting & remedies

6.1   New system or existing system

•  Check the immediate surroundings of the systems for changes that might cause

  malfunctions (for example, previously moved metal cabinets, furniture or walls). 

•  If radio switch/receiver work at a closer distance, there either might be interference

  or the system was used outside the transmission range. 

•  Placement of the radio switch at a more convenient location.

6.2   Radio signal range limitations

•  Use of the radio switch/receiver in the vicinity of metal objects or materials with

  metal components. Maintain a distance of at least 10 cm.

•  Moist materials.

•  Devices which emit high-frequency signals (e.g. audio and video systems, compu-

   ters, electronic ballasts in lightfixtures). Maintain a distance of at least 0.5 m.

6.3   Contact

Telefon:.................... 07720 694 447

Telefax:..................... 07720 694 239

Internet:.................... www.maico-ventilatoren.de

E-Mail:...................... [email protected]

7.   Conformity declaration

The DS-RC radio switch may be sold and operated in EU countries as well as in 

CH, IS and N. Maico herewith declares that the DS-RC radio switch is in compliance 

with the fundamental requirements and other relevant provisions of R&TTE Directive 

1999/5/EC.

O

I

Installation and operating instructions

DS-RC Radio Switch

Art-no.: 0157.0832

GB

Reviews: