Bedienungsanleitung 

Operating Instructions 

Notice d’utilisation 

LINEAR 100 

 

 

 

Linear 100 

Summary of Contents for LINEAR 100

Page 1: ...47000018 02 1 Bedienungsanleitung Operating Instructions Notice d utilisation LINEAR 100 Linear 100...

Page 2: ...g 50 100mm 9 4 2 3 Wellenmessung 9 4 2 4 Rundlauf Rundheitsmessung 10 4 3 Innenmessung 10 4 3 1 Preset und Nennma eingabe 10 4 3 2 Kalibrieren 11 4 3 3 Messen 11 5 Wartung und Pflege 11 6 Garantie 11...

Page 3: ...port 23 18 3 Support de pointe 23 18 3 1 Montage 24 18 3 2 Alignement du support de pointe 24 19 Mesure 25 19 1 R glage de l effort de mesure 25 19 2 Modification de la plage de mesure mesure ext rieu...

Page 4: ...d for correct function at regular intervals once daily by sufficiently qualified personnel The measuring device itself and all calibration standards which are implemented in connection with the measur...

Page 5: ...cking screw for centre mounting 8 Counter spindle fixing plate clamping lever 9 Adjustable height table for internal measurement 10 Star handle for measuring force setting 11 Knurling wheel for table...

Page 6: ...von Au en zu Innen Au engewindemessungen nach Drei Draht Methode 2 Aufstellen Transport 2 1 A u f s t e l e n 1 Ger t vorsichtig aus der Verpackung heben 2 Stellf e mit Sechskantschl ssel so verstell...

Page 7: ...n siehe Anzeige Die Spitzenaufnahme steht jetzt rechtwinklig zur Me achse 6 Mit Feststellschraube 3 klemmen 7 Abdeckkappe wieder aufstecken Zum Entfernen der Spitzenaufnahme nur Feststelschraube 3 l s...

Page 8: ...ereichs nderung Au enmessung 1 Klemmhebel 1 l sen und Gegenpinole 2 nach rechts bis zur gew nschten Position schieben 2 Danach wieder so festklemmen da sich die Gegenpinole beim Me vorgang nicht versc...

Page 9: ...w hlen 4 ENT Taste bet tigen Anzeige Einstellungen Passwort 5 Pa wort 9999 eingeben Anzeige richtig Passwort wird kurz angezeigt danach Einstellungen Grundeinstellung 6 ENT Taste bet tigen 7 Mit Pfeil...

Page 10: ...Presetspeicher ber Zahlentastatur eingeben 8 Mit der ENT Taste best tigen 9 MEN Taste dr cken 10 Pr fling einlegen und Ma in der Anzeige ablesen Die Kalibrierung der Kan le bleibt auch nach dem Umscha...

Page 11: ......

Page 12: ...des Einstellringes 30mm Ma des Pr flings ca 50mm Die Innenmessung ist im UMG Betrieb automatisch Kanal 2 zugeordnet Deshalb mit der CHA Taste auf Kanal 2 umschalten MAX und Preset Taste leuchten 4 3 1...

Page 13: ...sonst Fehlkalibrierung 4 3 3 Messen Vorgehensweise Bemerkung 1 Pr fling einlegen und verschieben Maximum berfahren Maximum Innen wird in der Anzeige festgehalten 5 Wartung und Pflege Das LINEAR 100 ni...

Page 14: ...s wird zus tzlich zu PIN J ber das Steckergeh use mit dem Geh use der Auswerteelektronik verbunden Bei Gebern mit getrenntem Innen und Au enschirm wird der Innenschirm ber Pin J auf GND gef hrt der Au...

Page 15: ...erkonstante Signalamplitude Stromquelle 4 bis 16 A s s Dam it ist sowohl die alte Heidenhainspezifikation 4 bis 11 Ass als auch die neue Heidenhainspezifikation 7 bis 11 Ass abgedeckt Steckerformen Au...

Page 16: ...external to internal External thread measurements using the three wire method 10 Setting up transporting 1 0 1 S e t t i n g u p 1 Remove the instrument from the packaging with care 2 Adjust with a he...

Page 17: ...3 2 Centre mounting adjustment 1 2 3 4 5 6 7 Clamp in a spindle of approx 15mm diameter Regulate measuring force 2 Set up gauge slides Remove cover 1 Move the adjusting screw 2 to find the minimum va...

Page 18: ...hanging the measuring range external measurement 1 Release clamping lever 1 and move counter spindle 2 to the right to the desired position 2 Then tighten again so that the counter spindle does not mo...

Page 19: ...d 5 Enter password 9999 Display richtig Passwort is displayed shortly after than Einstellungen Grundeinstellung 6 Press ENT button 7 Go to UMG operation with the up down arrow 8 Go to J with the left...

Page 20: ...et memory with the figure key pad Confirm with the ENT button Press MEN button 10 Insert the test piece and read off measurement from the display Channel calibration is retained even after switching b...

Page 21: ...ring measurement 30mm test piece measurement approx 50mm Internal measurement is automatically allocated to channel 2 in UMG operation Therefore use the CHA button to switch to channel 2 MAX and Prese...

Page 22: ...ring Procedure Comments 1 Insert test piece an adust laterally Maximum overshoot Maximum Internal held in the display 13 Maintenance and cleaning Never clean the LINEAR 100 with compressed air Once a...

Page 23: ...itter signal line screening is also connected to PIN J via the connector casing with the evaluation electronics casing When transmitting with separate internal and external screening the internal scre...

Page 24: ...stant Signal amplitude Current supply 4 to 16 A ss In this way both the old Heidenhain specification 4 to 11 Ass and the new Heidenhain specification 7 to 11 Ass are covered Connector types Evaluation...

Page 25: ...selon la m thode des trois fils 18 Installation transport 1 8 1 I n s t a l a t i o n 1 Sortir l appareil de l emballage avec pr cautions en le soulevant 2 A l aide d une cl fourche r gler les pieds s...

Page 26: ...u support de pointe 1 Monter un arbre de 15 mm de diam tre environ 2 R gler l effort de mesure 2 3 Mettre en place les inserts de mesure 4 D poser le capuchon de recouvrement 1 5 En actionnant la vis...

Page 27: ...la plage de mesure mesure ext rieure 1 Desserrer le levier de blocage 1 et repousser le contre fourreau 2 sur la droite jusqu la position voulue 2 Ensuite rebloquer de fa on ce que le contre fourreau...

Page 28: ...se 9999 Affichage richtig Passwort s affiche pendant une br ve p riode puis Einstellungen Grund einstellung 6 Appuyer sur la touche ENT 7 A l aide de la fl che Haut Bas se placer sur Mode UMG 8 A l ai...

Page 29: ...la m moire Preset 8 Valider par la touche ENT 9 Appuyer sur la touche MEN 10 Mettre en place l prouvette et lire la cote sur l afficheur L talonnage des canaux demeure m me apr s que l on soit pass de...

Page 30: ...r glage 30 mm dimension de l prouvette 50mm environ En mode UMG la mesure int rieure est automatiquement attribu e au canal 2 Par cons quent passer au canal 2 en appuyant sur la touche CHA les touches...

Page 31: ...n 20 3 3 Mesure Vorgehensweise Remarque 1 Mettre l prouvette en place et la d placer D passer le maximum Maximum Le int rieur est maintenu sur l afficheur 21 Entretien Le LINEAR 100 ne doit jamais tre...

Page 32: ...ligne de signaux du capteur est reli au bo tier de l lectronique d valuation par l interm diaire du bo tier des connecteurs Dans le cas de capteurs avec cran int rieur et cran ext rieur distincts l cr...

Page 33: ...e grille 20 m Amplitude des signaux Source de courant 4 16 A ss Ainsi r pond on aussi bien l ancienne sp cification Heidenhain 4 11 A s s qu la nouvelle 7 11 A ss Formes des connecteurs Electronique d...