DIAGNOSTIC MANUAL MAN-00201
QUANTO
EMS
SEP 2012/Rev 1
The repair methods given by the manufacturer in this document are based on the technical specifications, current at the time of release. The methods may be modified as a result of changes introduced by the
manufacturer in the production of the various component units and accessories from which the vehicles are manufactured. The reproduction, translation, transmission, in part of or whole of the present document,
are prohibited without the prior written consent of Mahindra & Mahindra Ltd. The use of this document by any person other than the trained personnel, at the Authorized Service Centre of Mahindra & Mahindra Ltd.,
will amount to unauthorized use and shall be liable for penalty/prosecution
© 2012 Mahindra & Mahindra Ltd.
`
P1714
GNS RELAY SHORT TO GROUND ERROR
GNS RELAY
GNS relay along with
starter relay runs the starter motor.The GNS relay is controlled by EMS ECU.
.
DTC INFORMATION
PROBABLE CAUSES OF FAILURE
NORMAL OPERATION
Ignition ON
No malfunction detected by EMS ECU in the control circuit of
GNS relay
DTC DETECTING CONDITIONS
Ignition ON
EMS ECU supply voltage 8-16V
Short to ground is detected in in the control circuit of GNS
relay
DTC REACTIONS
GNS relay always engaged
HEALING CONDITION
Ignition Off/On
Short to ground in GNS
relay control wire
Faulty GNS relay
Faulty EMS ECU
319