Section 3
Model GA8-TC 320
Emergency Procedures
CASA Approved
Page 3-6
5 Feb 2009
C01-01-08
3.3.3. Fires
During Start On Ground
1. Cranking ...............................................
CONTINUE,
to get a start which would suck the
flames and accumulated fuel through the fuel injector
and into the engine.
If engine starts:
2. Power ...................................................
1700 RPM
for a few minutes
3. Engine ..................................................
SHUTDOWN
and inspect for damage
If engine fails to start:
2. Cranking ..............................................
CONTINUE
3. Throttle .................................................
FULL OPEN
4. Mixture .................................................
IDLE CUT OFF
5. Fuel Shutoff Valve ................................
OFF
6. Ignition .................................................
OFF
7. Master Switches Bus 1 & Bus 2 ...........
OFF
8. Aircraft ..................................................
EVACUATE
and extinguish fire using best available means.
Engine Fire In Flight
1. Fuel Shutoff Valve ................................
OFF
2. Fuel Pump ...........................................
OFF
3. Throttle .................................................
CLOSED
4. Propeller ..............................................
COARSE
5. Mixture .................................................
IDLE CUT OFF
6. Cowl Flap .............................................
CLOSED
7. Master Switches Bus 1 and Bus 2 .......
OFF
8. Vents ....................................................
CLOSE HEATER AND AIR VENTS
9. Airspeed ...............................................
140 KIAS
to try to blow fire out.
INCREASE UP TO
V
NE
if required.
10. Forced Landing .................................. EXECUTE.
Refer paragraph 3.3.2
Electrical System Overheating In Flight
1. Master Bus 2 ........................................
OFF
2. Flight ....................................................
CONTINUE
cautiously
3. Land .....................................................
AS SOON AS PRACTICAL
Electrical Fire In Flight
1. Master Switches Bus 1 and Bus 2 .......
OFF
2. Electrical Switches ...............................
OFF
3. Extinguisher .........................................
ACTIVATE
If fire goes out:
4. Smoke .................................................. USE OXYGEN IF AVAILABLE.
VENTILATE CABIN
5. Precautionary Landing .........................
AS SOON AS PRACTICAL
01 Aug 2011
Summary of Contents for GIPPSAERO GA8-TC 320
Page 2: ...Section 0 Model GA8 TC 320 This page intentionally left blank...
Page 4: ...Section 0 Model GA8 TC 320 This page intentionally left blank...
Page 6: ...Section 0 Model GA8 TC 320 This page intentionally left blank...
Page 8: ...Section 0 Model GA8 TC 320 This page intentionally left blank...
Page 10: ...Section 0 Model GA8 TC 320 This page intentionally left blank...
Page 35: ...C01 01 08 5 Feb 2009 Page 2 13 Section 2 Model GA8 TC 320 Limitations...
Page 69: ...CASA Approved C01 01 08 13 Oct 2015 Page 5 3 Section 5 Model GA8 TC 320 Performance...
Page 70: ...Section 5 Model GA8 TC 320 Performance CASA Approved Page 5 4 13 Oct 2015 C01 01 08...
Page 77: ...CASA Approved C01 01 08 13 Oct 2015 Page 5 11 Section 5 Model GA8 TC 320 Performance...
Page 78: ...Section 5 Model GA8 TC 320 Performance CASA Approved Page 5 12 13 Oct 2015 C01 01 08...
Page 79: ...CASA Approved C01 01 08 13 Oct 2015 Page 5 13 Section 5 Model GA8 TC 320 Performance...
Page 80: ...Section 5 Model GA8 TC 320 Performance CASA Approved Page 5 14 13 Oct 2015 C01 01 08...
Page 146: ...Page 9 6 5 Feb 2009 C01 01 08 Section 9 Model GA8 TC 320 Supplements As Approved...