Operations
TPS II Eurosystem TRUCK
D1 1005BA1-GB01
9
6 Conduct the test
a. Enter the mileage of the vehicle via the
number keys of the keyboard or remote
control.
b. Confirm with <RETURN>.
c. Accelerate the vehicle to approx. 20
km/h.
Pay attention to the vehicle’s tachometer.
After a distance of 100 m is traveled press
<F5>. Repeat this process ten times.
⇒
The recorded test values and the
average travel distance will be displayed.
By pressing <F6> the recorded measuring
values will be deleted.
7 Terminate the test
If desired, the test can be aborted with the
<F8> key. The main screen of the
speedometer test appears:
Press <ESC> again to return to the main
menu. In the main menu select <3> „Select
measurement“. Select <6> „External
devices“, then <C> to review the
measuring values. The screen opposite
appears.
8 Exit the test stand with lift beam
Press <T> on the keyboard or on the
remote control. After the vehicle is lifted,
slowly exit the roller set in forward
direction.
The recorded measurement values are automatically taken over in the temporary memory. If the
test is repeated, the measuring values in the temporary memory will be overwritten.
Summary of Contents for TPS II
Page 4: ...TPS II Eurosystem TRUCK IV D1 1005BA1 GB01...
Page 6: ...TPS II Eurosystem TRUCK Safety 2 D1 1005BA1 GB01...
Page 17: ......