28
BA361601-en
Pos: 122 /Technis che Dok umentation/A lle G eräte/ Überschr iften/Üb erschriften 1.1/ F/Überschrift 1.1: Funktions- und Verschleißk ontr ollen @ 29\m od_1351069910594_ 75.d ocx @ 1667179 @ 2 @ 1
6.5
Operational and Wear Checks
Pos: 123 /Technis che Dok umentation/A lle G eräte/ Überschr iften/Üb erschriften 1.1.1/ T/Überschrift 1.1.1: Tragm utterverschleiß @ 38\mod_ 1403854694159_ 75.docx @ 2045798 @ 3 @ 1
6.5.1
Load Nut Wear Check
Pos: 124 /Technis che Dok umentation/Hebetechnik/ 36 Säulen-Hebebühnen/ 1601 ECONLIFT 6500/BA/I nhalt: 3616 Tragmutterverschleiß ( Tex t) @ 38\mod_ 1403854905585_75.d ocx @ 2045844 @ @ 1
Once a year check the load nuts for wear.
If load nut wear has been found, shut down and lock the lift until the load nut has
been replaced.
•
Raise the lift to approx. midpoint of travel and remove the plastic cap (3) from
the column cover.
•
Raise or lower the lift until the inspection window in the carriage (1) lines up with
the window in the column cover (2).
Pos: 125 /Technis che Dok umentation/Hebetechnik/ 36 Säulen-Hebebühnen/ 1601 ECONLIFT 6500/BA/I nhalt: 3616 Tragmutterverschleiß ( Bilder) @ 38\mod_ 1403855146429_0.docx @ 2045890 @ @ 1
Pos: 126 /Technis che Dok umentation/Hebetechnik/ 36 Säulen-Hebebühnen/ 1601 ECONLIFT 6500/BA/I nhalt: 3616 Verschleißkontrolle ( Tex t) @ 38\mod_ 1403855413093_75.d ocx @ 2045936 @ @ 1
Wear Check
The check screw now becomes visible in the inspection window.
A clearance of approx. 2 mm between check screw (1) and safety nut (2) is preset
at the factory.
If no clearance can be detected, have the load nut replaced prior to further use.
At completion of load nut wear check reinstall the plastic caps.
Pos: 127 /-----Format- ----/MANUE LLE R UMBRUCH Seitenumbruch @ 0\mod_ 1134403577687_0.docx @ 1277 @ @ 1