54
XCV 00000
Extrusion control voltage output value
XRC 00001
Rate of change of above value
TCV 00000
Takeoff equipment voltage output value
TRC 00004
Rate of change of above value
XTP 50050
Trip point to force a correction
XAL 00005
Percentage adjustment limit
XUL 00200
Voltage
adjustment
limit
The above 7 parameters all relate to Extrusion Control Systems.
MPO 00183
For air drive reciprocating mix motor.
Component Parameters
(12 Groups of 13 parameters each)
The first digit is the component number. Component 1 is shown here. There are 11 more just like it.
1TY = OFF
DESIGNATES MATERIAL TYPE for this component.
Material types are: REG, NAT, ADD, or OFF=NOT USED.
(0=OFF, 1=REG, 2=NAT, 3=ADD)
These MUST be set using the *14 function before the system will operate. See: "TURNING ON
OUTPUTS" to complete this.
1CS 00000
Thumbwheel assignment or current setting entry.
This parameter reflects the current setting or thumbwheel assignment for this component. No entry is required here.
1AL 00000
Last digit = number of retries before ALARM.
00001 to 00009 = sound alarm, hold process.
00011 to 00019 = sound alarm, continue process.
These parameters set ALARM functions. When material runs out, or does not dispense fully, these flags
instruct the controller what to do. Default settings shown are for Natural, Color, and Additive to alarm, but
not Regrind.
1XT 00000
Move decimal left on color and additive settings.
These parameters allow entry of less then (00.1) percent for COLOR or ADDITIVE.
When set to "00010" settings are read as X.XX percent.
When set to "00100" settings are read as .XXX percent.
1SE 01000
Upper SETTING limits for thumbwheels (0xxx.x).
Settings greater than limit are held to limit. (01000) = 100%
These parameters can SET UPPER LIMITS to the thumbwheels. For color and additive, lower settings
may help ensure expensive material is not wasted.
1WT 24000
WT/TI = the rate that will be used for calculating the next dispense time.
1TI 01952
WT = the Weight portion of the dispense rate, calculated such that WT/TI equals the average of the last
two actual dispense rates.
TI = the TIME portion of the dispense rate. (Interrupts)
These change AUTOMATICALLY during normal operation.
They are Weight and Time portions of the flow rate calibration.
1MI 00001
Minimum valid dump rate GRAMS/sec. (full or tenth grams)
Error correction is bypassed when dispense rate is lower.
On power up, these are always set to 1. After several consistent cycles, they are reset to 80 percent of
actual flow rate. These prevent excessive swings in flow rate calculations if material is running out.
1NC 00001
Allowable GRAM error within which NO correction is made.