KDF 00002
Maximum variation in GRAMS between two consecutive weight
WDF 00002
Readings for reading to be accepted. (x or x.x)
KDF controls sensitivity of weight readings during calibration of load cells. No change is required.
WDF controls the sensitivity of weight readings during normal operation. If excessive vibration interferes
with weight readings you may have to increase this number.
BER 00200
Excess GRAM weight before dispense is aborted.
This parameter controls sensitivity of the emergency "bailout" routine that prevents overfilling of the weigh
bin. No change is required.
ROC 00000
These three parameters help control regrind usage.
ROC indicates the PERCENT of REGRIND that will be treated as natural when COLOR and ADDITIVE
dispenses are calculated. This adds some color or additive to your regrind.
ROV 00000
ROV is for closed loop fully automatic reprocessing of regrind scrap. This parameter will detect when more
regrind is being produced than consumed, and override the current setting to use a higher amount. This
helps prevent material backing up in your grinder.
RHL 00000
RHL has effect only if level sensors are added to your unit to detect material level in the regrind hopper.
These level sensors can alter regrind percent usage.
FUL 09000
Full batch weight, determined by weigh bin size.
MAX 13500
Maximum GRAM weight the software will target.
FUL is the target weight that is blended each cycle. Change only for extremely fluffy or very heavy
material.
MAX prevents overflowing of the weigh bin. It is reset automatically if the FUL parameter is changed.
TH 01000
The highest and lowest acceptable TARE weights for
TL 00500
Blend cycle to start. (full or tenth grams)
TL prevents starting with the weigh bin out of place. No change is required.
TH prevents starting with a full weigh bin. Change TH only if clumps of material hang up in the weigh bin.
PRT 00000
MINUTE interval between automatic print of TOTALS.
This parameter will cause your system to PRINT MATERIAL TOTALS automatically. A printer must be
connected.
DLY 00488
Delay before cycle start. (Interrupts)
This parameter is the time that the sensor must be uncovered before a cycle will begin.
PRC 00010
Maximum allowable PERCENT rate change per cycle.
This prevents excessive swings in flow rates by the software. Do not change.
STL 00122
Dispense settle TIME before a weight reading is taken.
The time (interrupts) allowed for material to SETTLE in the weigh bin before a weight is taken. Lengthen
only to slow the next cycle start, thereby lowering the pile of material in the mix chamber, and, in some
cases, improving mixing.
LCL 00080
LOAD CELL limits, low slope, high slope, frequency, zero.
LCH 00120
DO NOT CHANGE except for different weight load cells.
LCF 00079
LCZ 00583
The above 4 parameters relate to the characteristics of the LOAD CELLS on your blender. DO NOT
CHANGE THEM.
DS1 00000
Thumbwheel switch override setting.
DS2 00000
The above 2 parameters allow external computer inputs to alter the thumbwheel switch settings. They are
used on computer controlled dispense systems, using MLAN software.