M P L   M L   S e r i e s   V e n t u r i   L o a d e r s

 

AVAILABLE MODELS 

 
All VENTURI LOADER MODELS use our aluminum venturi vacuum generator. 
 

MPL series loaders: 

 

  Are built on a two inch steel bar for easy mounting to the  

frame of a concentrate feeder or Weigh Scale Blender. 

  The air solenoid is visible on the bar. 

  Only ONE venturi loader can be controlled. 

 

MPL

  

has no separate control box. 

 

MPL-A

   has a control box with ALARM Strobe light and beeper. 

 

MPL-AS

  uses the same control box with an additional time delayed solenoid to activate a shut 

down procedure in the event the ALARM goes unattended. 

 

ML series loaders: 

 

  Do not use a steel bar for mounting. 

  The air solenoids are enclosed in the control box. 

  Up to FOUR venturies can be controlled from one box. 

  An ALARM feature is available, but no shut down function. 

 

ML-1:

    Controls 1 venturi only, for loading one hopper. 

 

The control panel accommodates ONE switch only. 

 

ML-2, ML-3, and ML-4: 

 

The control panel accommodates up to FOUR switches to 

 

control FOUR venturi loaders. 

 

The number installed determines the model number. 

 

Add "M" to the model number:   

 

when the unit is to be mounting on a MICRO Blender (ML-1M). 

 

Add "A" to the model number: 

 

when an ALARM function is required (ML-1A). 

 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for MPL Series

Page 1: ...MAGUIRE PRODUCTS INC MAGUIRE MPL Series ML Series VENTURI LOADERS INSTALLATION OPERATION MAINTENANCE Original Instructions Manual Revision Date April 8 2019 Copyright Maguire Products Inc 2019...

Page 2: ...M A G U I R E P R O D U C T S I N C 2 M P L M L S e r i e s V e n t u r i L o a d e r s...

Page 3: ...___6 Assembly __________________________________________________7 Installation Assembly Diagrams _______________________________9 Operation _________________________________________________16 Controls...

Page 4: ...pts no responsibility or liability for damage or malfunction of the equipment arising from non observance of these operating instructions To avoid errors and to ensure trouble free operation it is ess...

Page 5: ...additional time delayed solenoid to activate a shut down procedure in the event the ALARM goes unattended ML series loaders Do not use a steel bar for mounting The air solenoids are enclosed in the co...

Page 6: ...box is provided to mount inside the hopper lid to accept the inflow of material 6 SENSOR MOUNT red polypropylene installs in the hopper or lid 7 LEVEL SENSOR fits into the sensor mount 8 CONTROL BOX...

Page 7: ...p of the lid NOTE MPL series models with SUPPORT BAR Secure this hose to the SUPPORT BAR using the U bolt provided Adjust so that there is NO STRAIN on the hopper lid 4 Attach the other end of the red...

Page 8: ...g the existing sheet metal screws in the MCF controller WEIGH SCALE BLENDERS If this loader is to be used with a Weigh Scale Blender FEEDER then a bracket is provided Bolt this bracket to the plate th...

Page 9: ...M A G U I R E P R O D U C T S I N C 9 M P L M L S e r i e s V e n t u r i L o a d e r s DIAGRAMS VENTURI COLOR LOADER 7 PAGES Figure A...

Page 10: ...M A G U I R E P R O D U C T S I N C 10 M P L M L S e r i e s V e n t u r i L o a d e r s Figure B and C...

Page 11: ...M A G U I R E P R O D U C T S I N C 11 M P L M L S e r i e s V e n t u r i L o a d e r s Lid and lance details wide diagram...

Page 12: ...M A G U I R E P R O D U C T S I N C 12 M P L M L S e r i e s V e n t u r i L o a d e r s ML 1...

Page 13: ...M A G U I R E P R O D U C T S I N C 13 M P L M L S e r i e s V e n t u r i L o a d e r s ML 2 3 4...

Page 14: ...M A G U I R E P R O D U C T S I N C 14 M P L M L S e r i e s V e n t u r i L o a d e r s ML 2MB...

Page 15: ...M A G U I R E P R O D U C T S I N C 15 M P L M L S e r i e s V e n t u r i L o a d e r s WSB MB ML 2...

Page 16: ...es if this loader cycles on for only a few seconds it is an indication that the unit is loading quite well ALARM models If the letter A is part of the model designation on MPL A not the ML A then you...

Page 17: ...ial to the process 2 SWITCH POSITIONS UP for automatic operation MIDDLE position to prevent operation of the associated function DOWN position to force ON or TEST the associated function 3 PILOT LIGHT...

Page 18: ...r Be sure sensor is always fully seated in the sensor holder TROUBLESHOOTING FAILURE TO CONVEY MATERIAL 1 Check that air supply is adequate Check the PRESSURE GAUGE while loader is ON It should read b...

Page 19: ...M A G U I R E P R O D U C T S I N C 19 M P L M L S e r i e s V e n t u r i L o a d e r s Wiring Diagrams 3 pages...

Page 20: ...M A G U I R E P R O D U C T S I N C 20 M P L M L S e r i e s V e n t u r i L o a d e r s...

Page 21: ...M A G U I R E P R O D U C T S I N C 21 M P L M L S e r i e s V e n t u r i L o a d e r s...

Page 22: ...expressed or implied and of all other obligations or liabilities on our part and MAGUIRE PRODUCTS neither assumes nor authorizes any other persons to assume for it any other liability in connection w...

Page 23: ...m Web www maguire com Maguire Europe Tame Park Tamworth Staffordshire B775DY UK Tel 44 1827 265 850 Fax 44 1827 265 855 Email info maguire europe com Maguire Products Asia PTE LTD Main Office 15 Chang...

Reviews: