When the input voltage is below or over the specified voltage, the machine will cut off the power
to protect itself until the input voltage is available.
INSTALLATION
1. POWER
REQUIREMENT
- AC single phase 220V, 60 HZ with a 50 amp circuit breaker is required.
DO NOT OPERATE THIS UNIT if the ACTUAL power source voltage is less than 220 volts AC or
greater than 240 volts AC.
•
High voltage danger from power source! Consult a qualified electrician for proper
installation of receptacle. This welder must be grounded while in use to protect the operator
from electrical shock.
•
Do not remove grounding prong or alter the plug in any way. Do not use any adapters
between the welder's power cord and the power source receptacle. Make sure the POWER
switch is OFF when connecting your welder's power cord to a properly grounded 220 VAC,
60 HZ, Single Phase, 50 Amp input power supply.
2. EXTENSION CORD
- We do not recommend an extension cord because of the voltage drop they
produce. This drop in voltage can affect the performance of the welder. If you need to use an extension
cord, we recommend you check with a qualified electrician and your local electrical codes for your
specific area. Do not use an extension cord over 25 ft. in length.