background image

MAGNUM ZC GAS

INSTALLATION AND OPERATION MANUAL

The Magnum ZC Zero Clearance Wood/Gas burning appliance can be adapted for use either with
Wood or Gas.  Particular attention needs to be paid to the following guidelines for installation and
operation of your Magnum ZC appliance.

!

 

Installation requirements of the Magnum ZC appliance are the same whether you are installing
it for wood or gas.

!

 

2100-degree metal insulated or metal air-cooled venting must be used with wood and/or gas.

!

 

All clearance requirements are the same for gas as it is for wood burning.

!

 

Do not burn wood in a Magnum ZC that has been changed over to gas unless the gas log kit has
been removed by a professional service man trained to work on the Magnum ZC appliance.

!

 

Do not operate the Magnum ZC gas equipped appliance until you have read and understand the
operations section of this manual.

Summary of Contents for SP-40-ZC

Page 1: ...e are the same whether you are installing it for wood or gas 2100 degree metal insulated or metal air cooled venting must be used with wood and or gas All clearance requirements are the same for gas as it is for wood burning Do not burn wood in a Magnum ZC that has been changed over to gas unless the gas log kit has been removed by a professional service man trained to work on the Magnum ZC applia...

Page 2: ...box to get rid of ash and smoke buildup take out the bottom and side firebrick and put them in a box for storage in case the homeowner wants to have the unit changed back to wood at some time in the future take off the Fireplace doors and put them in a secure place or open them wide open Whether you are installing the gas option in a new unit or existing Magnum ZC appliance you will need to run a ...

Page 3: ...valve assembly bracket spark igniter bracket attaching screws NOTE Make sure that none of the parts are mixed up with the packaging and get thrown out Sift through the packaging carefully and then set the parts out of the way so that they do not get stepped on and broken Assemble the valve to the valve assembly bracket using the 2 10 24 X 3 8 long screws provided and the 2 10 washers Place the was...

Page 4: ...f within the required distance of the unit see the instructions included with the SP 40 ZC log set IMPORTANT You must pressure test the line before hooking onto the valve Excess pressure will destroy the valve Make sure that the inlet pressure is reduced to the correct pressure before hooking up the gas line to the valve see the instructions included with the SP 40 ZC log set Attach the pilot asse...

Page 5: ...instruction sheet Pour the sand or vermiculite in the pan and place the logs as shown Do not test fire the system until all fittings are checked for leaks Run the gas log for 30 minutes or more to make sure that all operations are working properly Go over the operation instructions with the customer to assure that they understand the system Fig 6 Front of unit SP 40 ZC Gas Log Assembly Gas log pla...

Reviews: