3.3 Table Stopper Adjustment
After moving the stop by fold guide fine adjustment dial,
make sure to press Test key before the Start/Stop key.
Otherwise, adjustment will not be accepted.
Note: If you press Start/Stop key, after adjusting the fold guide,
the fold guide will return to origin to fold.
When the stopper is moved largely, it will be convenient to use
the +/– key.
(A). Press the Select key and select the Table A Stopper Move
Mode. Press the +/- key and move the stopper to the desired
position.
(B). Press the Select key and select the Table B Stopper Move
Mode. Press the +/- key and move the stopper to the
desired position.
Note: To store the stopper position, after adjusting stopper by
using stopper fine adjustment knob or +/- key, please refer
to chapter 10 Storage.