![Magnum Intelligent Control User Manual Download Page 3](http://html1.mh-extra.com/html/magnum/intelligent-control/intelligent-control_user-manual_3609779003.webp)
6. Sensor selection
Floor or room sensor. If you choose
floor heating (Ref 1.2.4)
, we advise you to control the floor
temperature by using the floor sensor.
7. An overview wizard containing the current settings.
8. Choose temperature:
Program the comfort temperature of your choice for a heating period.
Standard temperature is programmed at 21 degree Celsius.
9. Choose temperature:
Program the setback temperature.
In the case of floor heating, it is not necessary to program the setback temperature.
The setback temperature is controlled by the thermostat automatically. (Ref 2.5).
10. Overview wizard containing the selected heating periods according the standard program.
11. Slow start up:
It is possible to choose this option (Ref 1.3 / point 7 slow start up).
Attention: After completion of the start up wizard, the main screen appears. Please do not
change any settings for 14 days as this allows the memory function of the thermostat to save
and adapt the historical data.
Mode (thermostat operating functions)
1. Temporary temperature:
To temporary override the temperature in the automatic program.
The override will operate until the next automatic event.
2. Automatic:
The thermostat will switch on according to the programmed settings. This can be the standard settings
or the custom time settings.
3. Manual control:
To permanently override the automatic program.
To cancel the manual mode, choose the automatic mode.
4. Off:
Turns the thermostat and the heating system off. Choose automatic mode to select the standard or the
custom time settings.
5. Timer:
Use this mode when you are on holidays etc. The thermostat will be off for the chosen period.
After this period, the thermostat will return to the standard or the custom time settings.
6. Frost protection:
In the case that the floor temperature falls below 7 degrees Celsius, the system starts heating and
keeps the temperature above 7 degrees.
To cancel this function, choose the automatic mode.
7.
Slow start up
:
To be used for new floors only. The thermostat will slowly raise the temperature of the floor over a 20
day period. After this period the thermostat automatically starts the standard or the custom time
programme. If you need to stop or restart the slow start up mode, press the left button.
Attention: When a mode function is in use, the symbol belonging to the function appears in the
main screen.
Menu (thermostat settings):
1. Temperature settings:
With this function you can change the programmed temperature (comfort or set back temperature).
Attention: In the case of floor heating, it is not necessary to program the setback temperature.
The setback temperature is controlled by the thermostat automatically. (Ref 2.5).