-     Adjustment up and down  
-     To scroll through settings 
 
 
Right button: 
 

Push right button in main screen to go straight to Menu settings (1.4) 

Confirming a choice 

-    Select an option 
 
Left button: 
 

Push left button in main screen to go straight to Mode functions (1.3) 

To get back to last screen or main screen 

 
 

Always go back to the main screen after making changes. 

 
 
 

 

 

 

Start up wizard: 

 
Start up menu/ wizard- 
 
After connecting power for the first time, it will take 5 minutes until the first question appears on the 
screen. This is due to the internal back up battery charging.  
By pushing the symbol 

 (right key) you confirm a choice and go to the next screen or option. 

If you want to change or check a choice in the start up menu you can press the symbol X (left key) and 
go back to the former screen or option.  
 

    1.  Language: 

-make your language choice. This is the first question in the start up menu. 
 
2. Preference choice 
-clock; choose 12 or 24 hour clock time (am/pm)  
-temperature; choose ºC or ºF scale 
 
3. Program date: 
-year; program the current year 
-month; program the current month 
-day number; program the current day 
-program time; program the actual clock time 
 
4. Type of (floor) heating: 
Floor heating or different heating system. If you choose a different heating system the thermostat 
switches straight to point 11 (below). 
 
Floor construction (if you choose floor heating) 
Program the floor depth of the underfloor heating installation. 
Choices: 

up to (<) 2 centimetres 

from 2 …….. 5 centimetres 

from 5……….10 centimetres 

more than (>) 10 centimetres 

 

5.  Floor covering: 

Wood or other. If you choose other, the question is asked if there is a floor sensor installed (yes or no). 
 

Summary of Contents for Intelligent Control

Page 1: ...LED colours signals Explanation of text symbols in main screen Intelligent function Standard automatic program Setback mode Heating new floors Energy consumption Back up battery Floor temperature limi...

Page 2: ...you can press the symbol X left key and go back to the former screen or option 1 Language make your language choice This is the first question in the start up menu 2 Preference choice clock choose 12...

Page 3: ...can be the standard settings or the custom time settings 3 Manual control To permanently override the automatic program To cancel the manual mode choose the automatic mode 4 Off Turns the thermostat a...

Page 4: ...en switched on allowing you to monitor your energy consumption The total switched on time is by percentage shown over the last 30 and 365 days Ref 2 8 4 Child lock The thermostat is locked with this f...

Page 5: ...his can be a central source or a smart home system This function can be turned on or off Sensor type gives the possibility to adjust the sensor value This is not required in a standard situation Consu...

Page 6: ...rying time before you turn on the floor heating For tiled floors a drying time of 3 4 weeks after installation should generally be observed Consult the supplier manufacturer regarding the applicable d...

Page 7: ...frame and the cover frame can be removed Position the thermostat and install onto the back box not supplied Place the display frame back into position by pushing it softly Attention When the power is...

Page 8: ...C F Technieken 2007 No rights can be...