 23

5.0 Specifi cations

5.0 Specifi cations

Table 5-1, CSW Series Specifi cations

Model 

CSW412

CSW1012

CSW2012

Electrical Specifi cations

Continuous Power

1

400 W

1000 W

2000 W

Surge Power (Peak)

2

800 W

2000 W

4000 W

AC Output Voltage (12.5V)

120 VAC RMS ± 5%

AC Output Current

3.3 AAC

8.3 AAC

16.6 AAC

AC Output Voltage Range

104-127 VAC

AC Output Frequency

60 Hz ± 0.5 Hz

AC Output Waveform

)

Pure sine wave (<3% THD)

AC Output Receptacle

NEMA 5-15, Dual GFCI with LED indicator

Optimum Ef

fi

 ciency

>90%

DC Input Voltage (Nominal)

12.5 VDC

DC Operation Voltage Range

3

10.5 - 15.75 

10.5 - 15.5 VDC

DC Input Current (Full Load)

38 DCA

94 DCA

187 DCA

DC Input Current (No Load)

<0.8 ADC

<1.2 ADC

<1.2 ADC

DC Output (USB port)

5V, 750 mA

Protection

Low Voltage Alarm

11.0 VDC

11.2 VDC

Low Voltage Shutdown

10.5 VDC

Low Voltage Recovery

12.0 VDC

11.8 VDC

High Voltage Shutdown

3

15.75 VDC

15.5 VDC

Output Power Warning

NA

Yes, with warning code

Output Power Shutdown

Yes

Yes, with shutdown code

Output Power Shutdown

Yes

Yes, with shutdown code

Temperature Warning

NA

Yes, with warning code

Temperature Shutdown

Yes

Yes, with shutdown code

Display Specifi cations

LED Status Indicator

Yes (Power, Fault)

Digital display

NA

volts in, power out, error codes

General Specifi cations

Operating Temperature

32° F to 104° F (0° C to 40° C)

Inverter Weight

3.8 lb (1.7 kg) 6.6 lb (3.0 kg) 11.5 lb (5.2 kg)

Inverter Size

(L x W x H)

CSW412:

7,9 x 6.9 x 3.4” (20 x 17.5 x 8.7 cm)

CSW1012:

12.6 x 6.9 x 3.4” (32.1 x 17.5 x 8.7 cm)

CSW2012: 

16.5 x 9.1 x 3.5” (41.9 x 23.0 x 8.9 cm)

Warranty

One Year

Regulatory Approval

Conforms to UL STD 458, Certified to CSA STD C22.2 No. 107.1

1: Specifications met when DC voltage at nominal (12.5V) and temp at 25°C.

2: 

Surge ratings are based on resistive load (output voltage may drop).

3: Damage can occur if input voltage exceeds 16 VDC.

Summary of Contents for CSW412

Page 1: ...Owner s Manual CSW Series Pure Sine Wave Inverter...

Page 2: ...s Restrictions on Use The CSW Series inverter may only be used in life support devices or systems with the express written approval of Sensata Technologies Failure of the CSW Series inverter can reaso...

Page 3: ...the inverter Always disconnect the batteries or energy source prior to installing or performing maintenance on the inverter Live power may be present at more than one point since an inverter utilizes...

Page 4: ...2 3 2 Torque Requirements 11 2 4 DC Wiring 12 2 4 1 DC Wire Sizing 13 2 4 2 DC Overcurrent Protection 14 2 4 3 DC Grounding 14 2 4 4 DC Cable Connections 14 2 4 5 Wiring the Battery Bank 15 2 4 6 Appl...

Page 5: ...Mounting Positions 9 Figure 2 4 CSW412 Dimensions 9 Figure 2 5 CSW1012 Dimensions 10 Figure 2 6 CSW2012 Dimensions 10 Figure 2 7 DC Cable to Battery Terminals 17 Figure 2 8 DC Cable to Inverter s DC...

Page 6: ...nit with a model specific prefix Note Enter your inverter s serial number in the table at the bottom of page i It is to easier to record this information now instead of trying to gather it after the u...

Page 7: ...shelf wall 10 DC Negative Terminal black the inverter s connection to the negative terminal on the 12 VDC battery bank 11 DC Positive Terminal red the inverter s connection to the positive terminal o...

Page 8: ...USB Port allows USB enabled devices to be powered and charged 4 ON OFF Power Switch a 2 position switch that turns the inverter on and off 5 Serial Number the unique identification number assigned to...

Page 9: ...ry compliance information 12 DC Positive Terminal red the inverter s connection to the positive terminal on the 12 VDC battery bank 1 3 Regulatory Compliance The CSW Series inverters are intended to b...

Page 10: ...should not be the determining factor as to whether the installation is compliant that is the responsibility of the electrician and the onsite inspector 2 1 1 Installation Guidelines Before connecting...

Page 11: ...S15 Transfer Switch CSW Series Inverter AC Loads 15A max DVD Tools TV AC Sub Panel AC Outlet DC Disconnect Fuse Battery Bank DC Ground Vehicle chassis DC ground bus or engine negative bus AC Main Pane...

Page 12: ...e pass thru mode the conductor from the transfer switch to the dedicated load will be protected as long as the branch rated circuit breaker at the AC source does not exceed the ampacity of the conduc...

Page 13: ...like gasoline or propane or in locations that require ignition protected devices Close to the battery bank As with any inverter it should be located as close to the batteries as possible Long DC wires...

Page 14: ...allation Mount flat on a horizontal surface only For Indoor Use Flat on a horizontal surface right side up or upside down DC terminals to the right left or the top Note The CSW inverter cannot be moun...

Page 15: ...on Figure 2 5 CSW1012 Dimensions Figure 2 6 CSW2012 Dimensions Top 10 3 26 2 cm 6 3 16 1 cm 6 9 17 5 cm 12 6 32 1 cm Front AC Side Back DC Side 3 4 8 4 cm Top 13 4 34 cm 8 5 21 6 cm 9 1 23 cm 16 5 41...

Page 16: ...ng must cross AC or vice versa try to make the wires at the crossing point perpendicular 90 degrees to one another DC overcurrent protection must be provided as part of the installation Use only coppe...

Page 17: ...e chance of radio frequency interference Be aware that over tightening or misthreading the nuts on the DC terminals can cause the bolts to strip and snap break off Make sure cables have a smooth bend...

Page 18: ...ppropriate overcurrent protection may be used if the inverter will only be connected to a dedicated load as shown in Figure 2 2 and the inverter and dedicated load have been thoroughly tested and sold...

Page 19: ...he metallic chassis of the various enclosures together to have them at the same voltage potential to reduce the possibility for electric shock For most installations the inverter chassis and the negat...

Page 20: ...able Also allow at least 1 2 5 cm of space between the batteries to provide good air flow DO NOT mount the batteries directly under the inverter CAUTION Install batteries in a well ventilated area Bat...

Page 21: ...bles to the inverter DC terminals a brief spark or arc may occur this is normal and due to the inverter s internal capacitors being charged 3 Route and connect an appropriately sized DC positive wire...

Page 22: ...al M6 1 0 hex nut CAUTION Ensure nothing is placed between the DC terminal and the ring lug CSW1012 Inverter lock washer 12 flat washer BATTERY DC cable with ring lug bolt flat washer nut lock washer...

Page 23: ...ctions to the inverter and batteries have been completed plug a small AC load e g 40W light bulb or small appliance into the GFCI s outlet and follow these steps to test the installation and the inver...

Page 24: ...to turn the unit off WARNING The Power ON OFF Switch is not a power disconnect switch and will not remove the DC power from the inverter Disconnect all power to the inverter before working on the unit...

Page 25: ...the unit has shut down Check the error code on the digital display When the status indicator lights amber or red use the digital display and the troubleshooting tables in Section 4 0 to resolve the is...

Page 26: ...he battery is fully charged If the cables are sized correctly the connections are good and the battery is charged you may need a larger battery bank see Loads turning on and off Loads turning off and...

Page 27: ...before restarting Check if the air flow is being blocked E05 Unit has sensed the input voltage is low and has initiated a warning alarm 11 2 VDC Recharge the battery to at least 11 8 VDC as the unit w...

Page 28: ...w Voltage Recovery 12 0 VDC 11 8 VDC High Voltage Shutdown3 15 75 VDC 15 5 VDC Output Power Warning NA Yes with warning code Output Power Shutdown Yes Yes with shutdown code Output Power Shutdown Yes...

Page 29: ...Sensata in Everett WA After the completion of service under this limited warranty Sensata will return the product prepaid to the original purchaser via a Sensata selected non expedited surface freight...

Page 30: ...PN 64 0063 Rev C Magnum Dimensions Products Manufactured by Sensata Technologies 2211 West Casino Rd Everett WA 98204 Phone 425 353 8833 Fax 425 353 8390 Web www Magnum Dimensions com...

Reviews: