- 34 -
M
AGNUM
-OP-EN
5. 7700:
Vacuum Motor circuit is open.
6. Throttle ERROR:
9OUPRESSEDTHEFOOTPEDALBEFORETURNING
on the key. Turn
OFF
the key and try again, leaving foot off of the
F
pedal.
7. 2C00 and 2C01 ERROR:
Low voltage warning. Voltage has
dropped down below the minimum required to operate the ma-
chine. If you wait a few minutes, the Batteries may come up in
voltage, allowing you to drive very slowly to the recharge station.
If not, you will have to release the parking brake (on the front
wheel, pull lever toward the front of the machine to release) and
PUSHTHEMACHINETORECHARGINGSTATION9OUMUSTDISCONNECTTHE
TRACTIONMOTORCABLElRST
8. 7802 ERROR:
The traction motor pulled excessive current
perhaps running a ramp for more than the 60 seconds allow-
ing for this. Turn
OFF
THE+EYTURNONAGAINANDCONTINUE9OU
F
should not use this machine to climb ramps so steep and so long
that this code comes up repeatedly, or you could overheat the
traction motor.
9. All other ERROR codes:
Turn
OFF
THE+EYANDDISCONNECTTHEPOSITIVEBATTERYCABLEFROMTHE"ATTERIESFORMORETHAN
F
one minute
(the time is needed to drain the controller on-board capacitor)
. Reconnect cables, being sure that it is tight.
Too loose and you will burn Battery. If you over tighten the cables you can damage the Battery lead terminal. Try
again.
10. If the problems cannot be solved by any of this solution, call your local dealer service department.