19
AC CONTROL PANEL/THERMOSTAT HOOK-UP
WARNING: ALWAYS DISCONNECT POWER CORD DURING ANY ELECTRICAL
OPERATION
1.
Remove control panel from protective packaging.
2.
Connect the one way molex plug to the control panel; do not pull on the wire harness inside
the stove.
NOTE: Use only a low voltage mercury or bi-metal thermostat switch. (No power required on
thermostat)
NOTE: If you are not going to use the thermostat function then skip steps #4 - #8 and go to Step #9.
3.
Locate the thermostat on a wall six (6’) to (10’) feet away.
4.
Route the wires into the stove near where the AC power cord enters.
5.
Pull the thermostat wire through to the control panel cut-out.
6.
Move the factory installed jumper from the upper position to the lower position. (see details
below)
7.
Connect the thermostat wires to the two terminals on the back of the control panel.
When the room temperature drops below the thermostat setting, the thermostat switch will
close, allowing the stove to operate at the medium or higher settings. When the room
temperature matches the thermostat setting, the thermostat switch will open, allowing the stove
to operate at the low setting.
8.
Locate the control panel into the side panel cut-out and secure with four (4) #7 X ½ Phillips
screws (supplied). Do not over tighten. Set control board to thermostat operation.
9.
The stove is now ready for operation. Refer to the
OPERATING INSTRUCTIONS.
Note: The thermostat function of the stove will cycle with the room temperature when the “Fuel
Feed Control” is set at a medium or higher setting.
LOW VOLTAGE
THERMOSTAT
MERCURY SWITCH
MOLEX
PLUG
.250
TERMINAL
QTY.- 4
#7 x 1/2"
SCREWS
AC POWER CORD
THERMOSTAT JUMPER
MUST BE MOVED TO
THIS POSITION
.250 TERMINAL SPADE
THERMOSTAT WIRE
CONNECTION
MOLEX PLUG
MOLEX PLUG
CONTROL PANEL
Must be in this
position
Summary of Contents for WINACI
Page 21: ...21 MAGNUM WIN INSERT INSTALLATION...
Page 25: ...25...
Page 26: ...26 Fireplace Insert Shroud Installation Diagram...
Page 27: ...27 Thermostat wire connection Low voltage thermostat Molex Plug 24 volt thermostat hookup...