VERTICAL INSTALLATION
GUIDELINES FOR CONNECTING TO AN EXISTING FACTORY-BUILT CHIMNEY:
1.
Inspect the chimney for the presence of creosote, soot or other combustible deposits, and blockage or
obstructions. Thoroughly clean the chimney and remove any obstructions.
2.
Thoroughly inspect the chimney for soundness, proper clearances and presence of all necessary parts, including a
chimney cap, prior to making the connection.
3.
This stove may be connected to an existing ceiling-mounted factory-built chimney with a diameter of 4”, 6”, or 8”
inches.
4.
Use a 3”-4”, 3”-6” or 3”-8” inch pellet vent to chimney adapter provided by the pellet vent manufacturer.
5.
Use only listed 3” inch Type PL pellet vent pipe between the stove and the chimney.
6.
Follow the pellet vent manufacturer’s instructions to assemble the vent pipe and make the connection to the
chimney.