2 . I N S T A L L A T I O N
5 . S t a r t - u p a n d T e s t ,
continued
C o n f ig u r in g t h e I n v e r t e r
T he R D S eries inv erter/ cha rger m us t be configured for Low B a ttery C utoff
( LB C O) , S hore Power C urrent, C ha rger Am ps , B a ttery S ize a nd B a ttery Ty pe. T hes e
opera tiona l pa ra m eters m us t be configured us ing the optiona l rem ote control.
R efer to the ME S eries R em ote C ontrol opera tor ’s m a nua l to configure the follow-
ing pa ra m eters :
S hore ( 5 , 1 0 , 1 5 , 2 0 , 3 0 , 5 0 )
AG S OFF
E na ble
Meter DC
AC
S etup S ea rch
LB C O
B a ttery B a nk
B a ttery Ty pe
C ha rge R a te
C ontra s t
Fa ctory R es et
Tech Tem ps
Fa ult R ecord
T he R D S eries inv erter/ cha rger a ls o a llows y ou to s elect a n equa lize cha rge for
the ba tteries . Pres s a nd hold the C ha rger ON/ OFF s witch for 4 s econds . T he E qua l-
ize ( E Q) function will be initia ted ( a nd the correct code will be s ent to the rem ote. )
T he E Q function a utom a tica lly term ina tes a fter 4 hours of opera tion. You ca n a ls o
m a nua lly s top the equa lize m ode by pres s ing a nd holding the C ha rger ON/ OFF s witch
while the inverter is in E Q m ode.
F u n c t io n
D e f a u lt
S ea rch
5 wa tts
LB C O
2 2 V DC
B a ttery B a nk
4 0 0 AHr
B a ttery Ty pe
Liquid Lea d Acid
C ha rge R a te
1 0 0 %
C ontra s t
7 5 %
T a b le 5 - F a c t o r y D e f a u lt S e t t in g s