2010 Magnum Energy, Inc
Page 39
Maintenance and Troubleshooting
1. Press and hold the Power
ON/OFF Switch.
2. Watch the Charging/Inverting
Status LED, after approximately
15 seconds it should come on
and
fl
ash rapidly to indicate the
inverter has reset. The Status LED
will go off after the Power ON/OFF
pushbutton is released.
4.3 Resetting the Inverter
Under some fault conditions (e.g., an internal fault), the inverter will need to be reset.
To reset the inverter:
Press and hold the Power ON/OFF pushbutton (see Figure 4-1) for approximately
fi
fteen (15)
seconds until the Charging/Inverting Status LED comes on and
fl
ashes rapidly; once the rapid
fl
ashing has begun, release the Power ON/OFF pushbutton. The Status LED will go off after
the pushbutton is released.
After the inverter reset is completed, press the ON/OFF pushbutton to turn the inverter ON.
Info:
The Power ON/OFF pushbutton is a small
momentary
type switch which operates
by lightly pressing and releasing.
Figure 4-1, Performing an Inverter Reset