2012 Magnum Energy, Inc.
Page 28
Installation
2.9.5
AC Wiring Confi gurations
The following table provides the different wiring con
fi
gurations for installing and connecting the
AC conductors into and out of the inverter (refer to Figures 2-12 to 2-15 for installation drawings
showing these con
fi
gurations).
Table 2-5, AC Input/Output Wiring Confi gurations
SI/SO (30A)
[Single In/
Single Out
(30A)]
SI/SO (60A)
[Single In/
Single Out
(60A)]
DI/SO
[Dual In/
Single Out]
DI/DO
[Dual In/
Dual Out]
AC Source
1
Required
120 VAC @ < 30
amps
120 VAC @
> 30 amps
(60 amps maximum)
120/240 VAC
(or two separate legs
of 120 VAC)
@ < 30 amps per leg
120/240 VAC
(or two separate legs
of 120 VAC)
@ < 30 amps per leg
Reason to
Use
Have a 120 VAC
source that is
< 30 amps.
Requires a
separate inverter
sub-panel
4
.
Have a 120 VAC
source that is > 30
amps.
Requires a
separate inverter
sub-panel.
Want dedicated
charging and
dedicated pass-thru
while the AC source
is on.
Requires a
separate inverter
sub-panel.
May need to power
240 VAC loads when
AC source is on
(requires 120/240
VAC source).
Requires a separate
inverter sub-panel.
Appropriate
MMP Models
MMP175-30D,
MMP250-30D
MMP175-60S,
MMP250-60S
MMP175-30D,
MMP250-30D
MMP175-30D,
MMP250-30D
Appropriate
Magnum
Inverter
Models
MS Series,
MS-AE Series,
MS-PAE Series,
RD Series
MSxx12, MS4024,
MS-AE Series,
MS-PAE Series,
RD Series
MSxx12,
MS4024,
RD Series
MSxx12, MS4024,
MS-AE Series,
MS-PAE Series,
RD Series
AC Input
Breaker
Provided
30A
(one pole of dual
pole breaker)
60A
(single pole)
30A
(dual pole)
30A
(dual pole)
Minimum AC
Wire Size
5
#10 AWG
(In & Out)
#6 AWG
(In & Out);
Can be split to two
#10 AWG
(for HOT 1
& HOT 2)
#10 AWG
(In & Out)
#10 AWG
(In & Out)
Maximum
Inverter
Pass-thru
Capacity
3600W
(30A @ 120 VAC)
5000W
2
(60A @ 120 VAC)
3600W
(30A @ 120 VAC)
5000W
2
(two legs of 30A
@ 120/240 VAC or
two legs of 30A @
120 VAC)
3
Wiring
Diagram
Figure 2-12
Figure 2-13
Figure 2-14
Figure 2-15
Note
1
: AC Source is from either the utility/grid power or an AC generator.
Note
2
: Enclosure capacity rated for 5000 Watts maximum.
Note
3
: If two legs of 30A @ 120 VAC are used, they must be from the same source.
Note
4
: The MS2012 and MS2000 models with integral branch circuit rated output breakers (i.e. MS2012-
20B) allows direct wiring from the unit to the load and do not require an inverter sub-panel.
Note
5
: Based on AC input breaker provided.