3.0 Operation
Operating a Basic MicroGT 500 PV System
To operate a batteryless MicroGT 500 inverter PV system:
1. Turn on the AC circuit breaker on each MicroGT inverter branch
circuit.
2. Turn on the main utility grid AC circuit breaker. Your system will
start producing power after a
fi
ve-minute wait time.
Note:
Five minutes after turning on the AC circuit breaker, the
units’ LEDs should start blinking green every 2 seconds. This
means they are producing power normally, but have not yet
connected to the MagWeb GT.
3. Plug in the MagWeb GT and follow instructions per your MagWeb
GT Owner’s Manual.
Once the MagWeb GT has been plugged in and acknowledges
the MicroGT inverters, the microinverters will start to blink
every 10 seconds.
Note:
The time required for all microinverters in the system
to report to the MagWeb GT will vary with the number of
microinverters in the system. Once communications have been
established between the MagWeb GT and the microinverters, the
microinverters will start to send performance data over power
line to the MagWeb GT. You can verify the proper operation of the
MicroGT inverters via the MagWeb GT.
Refer to the MagWeb GT Owner’s Manual for more information
on its operation.