2. INSTALLATION
3. Installation,
continued
Wiring the Inverter AC Input (refer to diagrams on the following pages) R e m o v e t h e c h a s s i s A C
a c c e s s c o v e r t o a c c e s s t h e i n t e r n a l t e r m i n a l b l o c k .
Route the cable and conduit from the main panel, approved bypass selector s w i t c h o r m a i n
A C p a n e l t o t h e i n v e r t e r ’ s A C I N P U T c o n d u i t c l a m p . T i g h t e n
t h e c l a m p s e c u r e l y o n t h e c o n d u i t . A l w a y s l e a v e a l i t t l e e x t r a s l a c k i n t h e w i r i n g .
C o n n e c t t h e h o t w i r e ( B L A C K ) f r o m t h e m a i n p a n e l ’ s d e d i c a t e d 3 0 a m p b r e a k e r t o t h e
“AC INPU T ( H O T 1 I N ) ” t e r m i n a l . T i g h t e n t h e s c r e w t e r m i n a l t o 1 6 i n c h -p o u n d s .
N O T E : I f u s i n g d u a l i n p u t s , c o n n e c t t h e R E D w i r e f r o m t h e m a i n p a n e l t o A C I N P U T
( H O T 2 I N )
C o n n e c t t h e n e u t r a l ( W H I T E ) f r o m t h e m a i n p a n e l ’ s n e u t r a l b u s b a r t o t h e “ A C
INPUT (NEU)” ter m i n a l . T i g h t e n t h e s c r e w t e r m i n a l t o 1 6 i n c h -p o u n d s .
Connect the ground (GREEN) wire from the main panel’s neutral bus bar to the “GROUND”
t e r m i n a l . T i g h t e n t h e t e r m i n a l t o 1 6 i n c h -p o u n d s .
Wiring the Inverter AC Output (refer to diagrams on the following pages) R o u t e t h e c a b l e a n d
c o n d u i t f r o m t h e A C d i s t r i b u t i o n p a n e l t o t h e i n v e r t e r ’ s A C O U T P U T c o n d u i t c l a m p .
T i g h t e n t h e c l a m p s e c u r e l y o n t h e c o n d u i t .
C o n n e c t t h e h o t ( B L A C K ) w i r e t o t h e “ A C O U T P U T 1 ( H O T ) ” t e r m i n a l . T i g h t e n t h e
terminal to 16 inch-pounds.
N O T E : I f u s i n g d u a l o u t p u t s , c o n n e c t t h e R E D w i r e t o t h e “ A C O U T P U T 2 ( H O T ) ”
terminal.
C o n n e c t t h e n e u t r a l ( W h i t e ) w i r e t o t h e “ A C O U T P U T ( N E U ) ” t e r m i n a l . T i g h t e n t h e
terminal to 16 inch-pounds.
C o n n e c t t h e g r o u n d ( G r e e n ) w i r e t o t h e “ G R O U N D ” t e r m i n a l . T i g h t e n t h e t e r m i nal to
16 inch-pounds.
Final Inspection
V e r i f y a l l c a b l e s / c o n d u i t r u n s a r e s e c u r e d w i t h w i r e t i e s o r o t h e r n o n c o n d u c t i v e
fasteners to prevent chafing or damage from movement and vibration.
Verify strain reliefs or grommets are in place to prevent damage to the wiring or conduit where it
passes through walls, bulkheads or other openings.
V e r i f y a l l A C c o n n e c t i o n s a r e c o r r e c t a n d t o r q u e d t o 1 6 i n c h p o u n d s .
R e p l a c e t h e c o v e r s o n t h e m a i n e l e c t r i c a l / d i s t r i b u t i o n p a n e l . R e p l a c e
t h e c h a s s i s a c c e s s c o v e r .
V e r i f y t h e i n v e r t e r ’ s f r o n t p a n e l s w i t c h i s i n t h e " O F F " p o s i t i o n .
N O T E : I f r e q u i r e d b y c o d e , h a v e t h e i n s t a l l a t i o n i n s p e c t e d b y a n e l e c t r i c a l i n s p e c t o r .
Ó 2003 - Magnum Energy, Inc.
21
Summary of Contents for ME Series
Page 1: ...ME Series Inverter Chargers Operator s Manual ...
Page 7: ...1 INTRODUCTION Figure 1 ME Series Inverter Charger Ó 2003 Magnum Energy Inc 2 ...
Page 15: ...10 Ó 2003 Magnum Energy Inc ...
Page 20: ...combined battery capacity 400 AHr 12 VDC 14 Ó 2003 Magnum Energy Inc ...
Page 24: ...Ó 2003 Magnum Energy Inc 17 ...
Page 33: ...Ó 2003 Magnum Energy Inc ...
Page 45: ...Remote Control for ME Series Inverter Chargers Operator s Manual ...
Page 47: ......
Page 50: ...3 Operation Figure 2 Remote Control Font Panel Ó 2003 Magnum Energy Inc 4 ...
Page 61: ...1 0 TROUBLESHOOTING 1 1 ME SERIES 1 2 RD SERIES 1 3 REMOTE ...
Page 62: ...2 0 REPAIRING OVERVIEW ...
Page 63: ......
Page 73: ......
Page 74: ......
Page 75: ......
Page 76: ......
Page 77: ......