4.0 Using LED Indicators to Determine MagWeb’s Status

4.2 MagWeb Wired Ethernet LED Status

4.2.1 LEDs Below the Ethernet Port

Normal operation is amber or green for the Link LED and periodic fl ashing of 

the Activity LED.

Note:

 

Refer to Figure 4-1 (Back View) to determine the positions of the 

Activity and Link bi-color LEDs within the MagWeb’s Ethernet port.

Table 4-2, Functions of LEDs Below the Ethernet Port

Link LED 

Activity LED

Color

Meaning

Color

Meaning

Off

No Link

Off

No Activity

Amber

10 Mbps

Amber

Half Duplex¹

Green

100 Mbps

Green

Full Duplex²

Note 1 - Data transfers between Magnum’s servers and the MagWeb system 

can only transmit in one direction at a time (not simultaneously).
Note 2 - Data transfers between Magnum’s servers and the MagWeb system 

can transmit in both directions at the same time (simultaneously).

Summary of Contents for MagWeb Wired Ethernet

Page 1: ...Owner s Manual ME MW E MagWeb Wired Ethernet ...

Page 2: ... installing or using this product All electrical work must be performed in accordance with local state and federal electrical codes This product is designed for indoor compartment installation It must not be exposed to rain snow moisture or liquids of any type Use insulated tools to reduce the chance of electrical shock or acciden tal short circuits Remove all jewelry such as rings watches bracele...

Page 3: ...p the MagWeb Device 4 2 2 1 Connecting MagWeb to a Local Area Network and the Internet 6 2 2 2 Connecting MagWeb to a Single Inverter 6 2 2 3 Connecting MagWeb to a Single Inverter and Remote Control 6 2 3 Configuring the Local Area Network 6 2 4 Registering on data magnumenergy com 6 3 0 Using data magnumenergy com 6 4 0 Using LED Indicators to Determine MagWeb s Status 7 4 1 MagWeb Device LED St...

Page 4: ...ustration of MagWeb Device 1 Figure 2 1 MagWeb System Diagram 3 Figure 2 2 MagWeb Dimensions 5 Figure 4 1 MagWeb Wired Ethernet LED Diagram 9 List of Tables Table 4 1 MagWeb Device s LED Indicator Guide 7 Table 4 2 Functions of LEDs Below the Ethernet Port 8 ...

Page 5: ... monitor and the automatic generator start module Using your always on internet connection the MagWeb system makes live and historical conditions available via a web browser and our data magnumenergy com service The MagWeb system uses the sensors and controllers already built into Magnum products There are no external sensors to install configure or calibrate Figure 1 1 Illustration of MagWeb Devi...

Page 6: ...n and out Inverter stack mode AC frequency Status including fault s Invert and Charge LEDs DC volts Battery temperature DC amps Transformer temperature AC volts out FET temperature 1 2 2 Inverter Remote Compatible with all versions of Magnum s Standard Remote Control ME RC50 Advanced Remote Control ME ARC50 and Router ME RTR For PAE systems using the Magnum router the current MagWeb firmware will ...

Page 7: ... be performed by qualified person nel such as a licensed or certified electrician It is the install er s responsibility to determine which safety codes apply and to ensure that all applicable installation requirements are followed Applicable installation codes vary depending on the specific location and application Info The MagWeb is plugged directly into a wired Ethernet connection using the supp...

Page 8: ...tion that is dry and away from extreme temperatures Use the two supplied 8 x 3 4 screws to securely affix the module Allow ample room to view the MagWeb device s LED and to access all connectors CAUTION Do not mount the MagWeb device in a closed battery compartment or in an area where water or any other liquid can enter the device and cause shorting or corrosion Failure due to improper mounting is...

Page 9: ...MagWeb Dimensions Side view Top view 0 9 in 23 mm 3 3 in 83 mm 0 6 in 15 mm 4 5 in 113 4 mm 1 2 in 30 mm 0 06 in 1 5 mm 2 13 in 54 mm 4 5 in 113 4 mm 3 3 in 83 mm 3 87 in 98 3 mm 1 14 in 29 1 mm 0 2 in 5 2 mm 0 39 in 10 mm 0 495 in 12 4 mm 0 315 in 7 55 mm ...

Page 10: ... Area Network LAN Ethernet network using the supplied 8 conductor CAT5 Ethernet cable This connection is made directly to a network access device such as a router or through a wall jack that connects to a network access device Info The MagWeb is plugged directly into a wired Ethernet connection using the supplied Ethernet cable The Ethernet cable run is limited to 100 meters in total length The Et...

Page 11: ... cables are correctly seated into the MagWeb device Red ON Green ON Red ON Green ON Power up sequence 1 second interval between each color The MagWeb device is performing a self test this occurs when first connected to power Green ON Normal operation the MagWeb device is correctly transmitting and receiving with network devices Green BLINKING Remote not connected or device is not able to communica...

Page 12: ...ity and Link bi color LEDs within the MagWeb s Ethernet port Table 4 2 Functions of LEDs Below the Ethernet Port Link LED Activity LED Color Meaning Color Meaning Off No Link Off No Activity Amber 10 Mbps Amber Half Duplex Green 100 Mbps Green Full Duplex Note 1 Data transfers between Magnum s servers and the MagWeb system can only transmit in one direction at a time not simultaneously Note 2 Data...

Page 13: ...or LEDs Link Activity Ethernet RJ11 Jack To Inverter RJ11 Jack To Remote SN MW50000 PN ME MW E Back View Top View Front View 2011 Magnum Energy Inc 9 Figure 4 1 MagWeb Wired Ethernet LED Diagram 4 0 Using LED Indicators to Determine Magweb s Status ...

Page 14: ...evice Did you refer to Tables 4 1 and 4 2 to learn what the LED signals were communicating to you 5 2 Troubleshooting Questions and Answers What is this device on my network The MagWeb device allows remote monitoring of Magnum Energy invert ers and accessories Physically it is a small black box with an Ethernet cable and three LEDs How does it communicate When the first data is received from the M...

Page 15: ...d off Verify that you can reboot your computer and then use a web browser to visit http data magnumenergy com If you cannot connect then the network connection will not work for the MagWeb The most likely problem is a network log in requirement or a firewall that does not allow outgoing data connections What if I still have questions Visit www magnumenergy com or call the Magnum Energy offices at ...

Page 16: ...liant no lead used in manufacture Weight and Dimensions Shipping Weight 1 pound Dimensions l x w x h 4 5 x 2 2 x 1 2 114mm x 54mm x 30mm Kit Includes MagWeb Wired Ethernet Owner s Manual Remote cable 4 conductor 6 ft twisted pair telephone standard Mounting screws Ethernet cable 6 ft Requirements Access to an always on internet connection that is capable of sending approxi mately 2 5 megabytes of ...

Page 17: ...by the price paid by the original purchas er Magnum Energy shall not be liable for any other losses or damages 4 Upon request from Magnum Energy the original purchaser must prove the product s original date of purchase by a dated bill of sale itemized receipt 5 The original purchaser shall return the product prepaid to Magnum Energy in Everett WA After the completion of service under this limited ...

Page 18: ...g your product directly to Magnum Energy for repair you must return the unit in the original or equivalent shipping container receive a Return Materials Authorization RMA number from the factory prior to the return of the product to Magnum Energy for repair place RMA numbers clearly on the shipping container or on the packing slip When sending your product for service please ensure it is properly ...

Page 19: ...Magnum Energy Inc 2211 West Casino Rd Everett WA 98204 Phone 425 353 8833 Fax 425 353 8390 Web www magnumenergy com PN 64 0055 Rev A ...

Reviews: