CSW-RS Owner’s Guide
© 2013 Magnum Energy, Inc.
3
Functional Test
After installing and connecting the remote, use the following steps to ensure
the remote functions correctly.
1. Turn the inverter on using the inverter’s Power/Select button.
2. Verify the Status indicator light on the inverter and the green indicator light
on the remote both come on.
3. Press the switch on the remote to turn the inverter off, and then verify the
green indicator light on the remote and the status indicator on the inverter
both go off.
4. Press the switch on the remote again to turn the inverter on, and verify
the green indicator light on the remote comes on.
If the remote passes all the above steps, it’s ready for use.
If the remote fails any of the steps, check all the connections at both ends of
the remote cable and ensure the inverter is operational. If the status indicator
on the inverter comes on red (error), refer to the Troubleshooting section in
the CSW1012 Owner’s Manual to help clear the error condition.
Operation
The CSW-RS uses a momentary rocker switch that duplicates the Power/Select
button on the inverter, and functions by momentary pressing for one second
and releasing. This remote switch also provides a green LED indicator to show
whether the CSW1012
inverter is ON or OFF.
To turn the inverter ON: Press and hold the rocker switch on the remote for
approximately one second. When the green light on the remote switch comes
on, the inverter is ON.
To turn the inverter OFF: Turn the inverter off by pressing and holding the rocker
switch on the remote for approximately one second. When the green light on
the remote switch turns off, the inverter is OFF.
WARNING: The remote switch turns the inverter’s control circuit
on and off. This switch is not a power disconnect switch and will
not remove the DC power from the inverter. Disconnect all power
to the inverter before working on the inverter.