USER MANUAL
C
FLEX
TM
PROGRAMMING
TOOL
Page 2
Standalone Operation - How to Use the Programming Tool
The Programming Tool enters SIMPLEMODE operation
automatically after powering up with a short BEEP sound
indicating its valid hardware self-checks. The LED digits
will then display “
SIMP
”-“
ModE
”. This is the mode used
for standalone operation.
Programming Parameters
Press the “
M
” button to switch items between “current
setting” (mA indicator light) and “voltage setting” (V
indicator light) with “
ISET
”/ “
VSET
” display indication.
Note:
“
ISET
” is the only setting available for the Magnitude
CFLEX. “
VSET
” setting is reserved for future use as are
the “
ADR
” and “
%
” settings.
Press the “
+
” or “
-
” button to adjust the shown decimal value to setting. Hold the
button down and it will scroll faster. Release the button to stop.
Press the “
Program
” button to program current setting value into the LED driver.
After successful writing, the Controller will beep then show “
OK
” and the setting
value in alternative cycling. If the process fails, it will show “
E-02
” or “
E-03
” error
codes.