background image

USER MANUAL

C

FLEX

TM

PROGRAMMING

TOOL

Page 2

Standalone Operation - How to Use the Programming Tool

The Programming Tool enters SIMPLEMODE operation 

automatically after powering up with a short BEEP sound 

indicating its valid hardware self-checks. The LED digits 

will then display “

SIMP

”-“

ModE

”.  This is the mode used 

for standalone operation.

Programming Parameters

Press the “

M

” button to switch items between “current 

setting” (mA indicator light) and “voltage setting” (V 

indicator light) with “

ISET

”/ “

VSET

” display indication. 

Note:

  “

ISET

” is the only setting available for the Magnitude 

CFLEX. “

VSET

” setting is reserved for future use as are 

the “

ADR

” and “

%

”  settings.

Press the “

+

” or “

-

” button to adjust the shown decimal value to setting. Hold the 

button down and it will scroll faster. Release the button to stop.

Press the “

Program

” button to program current setting value into the LED driver. 

After successful writing, the Controller will beep then show “

OK

” and the setting 

value in alternative cycling. If the process fails, it will show “

E-02

” or “

E-03

” error 

codes.