OPERATOR’S MANUAL
with Maintenance Information
Maintenance
71
Note: The following must be measured and
recorded once the battery has been fully
charged, after a waiting time of at least 12
hours:
- Total voltage
- Individual voltage of the block battery
If significant changes to previous
measurements or differences between the
block batteries are identified, then customer
service must be contacted for further testing or
repairs.
Note: If you have any further questions
regarding the battery charger operation,
please contact the DINGLI Service
Department.
B-2
Inspect the Electrical Wiring
DINGLI requires that this procedure be
performed every 250 hours or quarterly,
whichever comes first.
Maintaining electrical wiring in good condition
is essential to safe operation and good
machine performance. Failure to find and
replace burnt, chafed, corroded or pinched
wires could result in unsafe operating
conditions and may cause component
damage.
Electrocution / burn hazard.
Contact with electrically charged circuits could
result in death or serious injury. Remove all
rings, watches and other jewelry.
1 Inspect the underside of the chassis for
damaged or missing ground strap(s).
2 Inspect the following areas for burnt,
chafed, corroded and loose wires:
•
Ground control panel
•
Hydraulic power unit module tray
•
Battery pack module tray
•
Platform controls
3 Turn the key switch to ground control. Pull
out the platform and ground red
Emergency Stop button to the on position.
4 Raise the platform until the distance of the
two sets of scissor at least 0.5m.
5 Lift the safety arm, move it to the center of
the scissor arm and rotate up to a vertical
position.
6 Lift the upper safety arm, move it to the
center of the scissor arm and rotate down
to a vertical position. (for ES1412H/E,
ES1612HLB/ELB, ES1612HCP/ECP).