BULLETIN:  57-651.4
EFFECTIVE:  January 2018
SUPERSEDES:  March 2012

705 Enterprise Street • Aurora, Illinois 60504-8149 • 630-969-4000
[email protected] • www.magnetrol.com

Copyright © 2018 Magnetrol International, Incorporated

Service Policy

Owners of MAGNETROL controls may request the return
of a control or any part of a control for complete rebuilding
or replacement. They will be rebuilt or replaced promptly.
Controls  returned  under  our  service  policy  must  be
returned  by  prepaid  transportation.  MAGNETROL  will
repair or replace the control at no cost to the purchaser (or
owner) other than transportation if:

1.  Returned within the warranty period; and
2.  The factory inspection finds the cause of the claim to

be covered under the warranty.

If the trouble is the result of conditions beyond our con-
trol;  or,  is  NOT  covered  by  the  warranty,  there  will  be
charges  for  labor  and  the  parts  required  to  rebuild  or
replace the equipment.

In  some  cases  it  may  be  expedient  to  ship  replacement
parts;  or,  in  extreme  cases  a  complete  new  control,  to
replace the original equipment before it is returned. If this
is desired, notify the factory of both the model and serial
numbers of the control to be replaced. In such cases, cred-
it  for  the  materials  returned  will  be  determined  on  the
basis of the applicability of our warranty.

No claims for misapplication, labor, direct or consequen-
tial damage will be allowed. 

Return Material Procedure

So  that  we  may  efficiently  process  any  materials  that  are
returned,  it  is  essential  that  a  “Return  Material
Authorization”  (RMA)  number  be  obtained  from  the
factory  prior  to  the  material’s  return.  This  is  available
through a MAGNETROL local representative or by con-
tacting the factory. Please supply the following information:

1.  Company Name
2.  Description of Material
3.  Serial Number
4.  Reason for Return
5.  Application

Any  unit  that  was  used  in  a  process  must  be  properly
cleaned in accordance with OSHA standards, before it is
returned to the factory.

A Material Safety Data Sheet (MSDS) must accompany
material that was used in any media.

All shipments returned to the factory must be by prepaid
transportation.

All replacements will be shipped F.O.B. factory.

ASSURED QUALITY & SERVICE COST LESS

ECLIPSE Guided Wave Radar transmitters may be protected by one or more of the following U.S. Patent Nos.
US 6,626,038; US 6,640,629; US 6,642,807; US 6867729; US 6879282; US 6906662. May depend on model.

Disclaimer

MAGNETROL accepts no liability whatsoever for the use of these numbers or for the correctness of the standards on
which the general calculation methods are based.

References

• IEC 61508-1: 2010-04
• IEC 61508-2: 2010-04
• IEC 61508-3: 2010-04

Magnetrol, Magnetrol logotype and Eclipse are registered trademarks of Magnetrol International, Incorporated.
F

OUNDATION

fieldbus logo is a registered trademark of the Fieldbus Foundation.

HART is a registered trademark of the HART Communication Foundation.
PACTware is trademark of PACTware Consortium.
PROFIBUS is a registered trademark of PROFIBUS International.

 

Summary of Contents for Eclipse 705-51A Series

Page 1: ...omer specified out of range signal i e less than 3 8 mA or greater than 20 5 mA The Enhanced Model 705 is certified for use in low or high demand level measurement applications Application The Enhance...

Page 2: ...l Level of Personnel 6 5 3 Necessary Tools 6 5 4 Storage 7 5 5 Installation 7 5 6 Configuration 7 5 6 1 General 7 5 6 2 SIS Configuration Requirements 8 5 6 3 Write Protecting Locking 8 5 7 Site Accep...

Page 3: ...ssified as a Type B Device as defined by IEC61508 NOTE Please ensure that the Model 705 transmitter and probe are installed as a set matched by the Serial Number shown on the name plates 1 3 Determini...

Page 4: ...This SIL 2 3 certified device is only available with an analog signal 4 20 mA with HART digital communications The measurement signal used by the logic unit must be the generated analog 4 20 mA signa...

Page 5: ...equipment etc with smaller transient volt ages than those characteristic of Overvoltage Category III This category applies from the wall plug to the power sup ply isolation barrier or transformer The...

Page 6: ...ildup on the probe Refer to Section 3 3 3 of Installation and Operating Manual 57 600 for more detailed application information regarding media buildup and bridging 5 1 2 Environmental Refer to Sectio...

Page 7: ...nd resetting of the password protection function Section 2 6 5 1 of I O Manual 57 600 provides menu selec tion items for configuration of the transmitter as a Level Only sensing device See Section 5 6...

Page 8: ...eplate MEASUREMENT TYPE Level Only LEVEL UNITS As indicated on probe nameplate PROBE LENGTH As indicated on probe nameplate LEVEL OFFSET As required by application DIELECTRIC As required by applicatio...

Page 9: ...ete a site acceptance test should be performed to ensure proper opera tion This procedure is identical to the Proof Test Procedure described in Section 6 1 4 of this manual Record the results for futu...

Page 10: ...in the Safety Integrity Level of a Safety Instrumented System it is imperative that specified manual proof testing be completed at the time intervals specified The user must select the type of inspect...

Page 11: ...level from the probe The Status parameter should say Dry Probe and the level reading should be equal to the value in the Level Offset parameter 5 Perform a two point calibration check of the transmit...

Page 12: ...ilistic calculation method is meaningless as the probability of failure significantly increases with time The useful lifetime is highly dependent on the component itself and its operating conditions t...

Page 13: ...endently verify all changes to end user configured parameters and validate the safety functionality prior to reliance on the product for safety protection End user s responsibility SSA 8 The end user...

Page 14: ...14 57 651 Eclipse SIL Certified Safety Manual for Enhanced Model 705 51AX XXX 8 2 FMEDA Report exida Management Summary...

Page 15: ...15 57 651 Eclipse SIL Certified Safety Manual for Enhanced Model 705 51AX XXX...

Page 16: ...al Procedure So that we may efficiently process any materials that are returned it is essential that a Return Material Authorization RMA number be obtained from the factory prior to the material s ret...

Reviews: