SEALED CAGE MODEL DIMENSIONAL SPECIFICATIONS in mm (inches)

Carbon steel and Stainless steel chambers with 1" and NW 25 (DIN) connections.

mm

1" NPT & socket weld

1" or NW 25

1" or NW 25

Flanged upper side / bottom

Flanged side / side

Part n° code

A

B

C (max)

D

E

F (max)

G

H

J (max)

A75

222

82

605

356

185

738

356

185

738

B75

222

95

579

356

200

713

356

200

713

C75

222

95

579

356

200

713

356

200

713

G75

242

109

609

356

215

723

356

215

723

J75

242

109

609

356

215

723

356

215

723

P75*

222

82

567

356

185

701

356

185

701

O75*

222

70

561

356

165

695

356

165

695

inches

1" NPT & socket weld

1" or NW 25

1" or NW 25

Flanged upper side / bottom

Flanged side / side

Part n° code

A

B

C (max)

D

E

F (max)

G

H

J (max)

A75

8.74

3.23

23.80

14

7.28

29.05

14

7.28

29.05

B75

8.74

3.74

22.79

14

7.87

28.07

14

7.87

28.07

C75

8.74

3.74

22.79

14

7.87

28.07

14

7.87

28.07

G75

9.53

4.29

23.97

14

8.46

28.46

14

8.46

28.46

J75

9.53

4.29

23.97

14

8.46

28.46

14

8.46

28.46

P75*

8.74

3.23

22.32

14

7.28

27.60

14

7.28

27.60

O75*

8.74

2.75

22.08

14

6.50

27.36

14

6.50

27.36

*  316 / 316L stainless steel only

Carbon steel and Stainless steel chambers with 1 1/2" and NW 40 (DIN) connections.

mm

1 1/2" NPT

1 1/2" socket weld

1 1/2" or NW 40

1 1/2" or NW 40

Flanged upper side / bottom

Flanged side / side

Part n° code

A

B

C (max)

A

B

C (max)

D

E

F (max)

G

H

J (max)

A75

222

84

605

222

93

605

356

200

738

356

200

738

B75

217

98

584

225

108

592

356

215

723

356

215

723

C75

217

98

584

225

108

592

356

215

723

356

215

723

G75

236

114

613

243

122

620

356

230

733

356

230

733

J75

236

114

613

243

122

620

356

230

733

356

230

733

P75*

217

84

573

224

93

580

356

200

712

356

200

712

inches

1 1/2" NPT

1 1/2" socket weld

1 1/2" or NW 40

1 1/2" or NW 40

Flanged upper side / bottom

Flanged side / side

Part n° code

A

B

C (max)

A

B

C (max)

D

E

F (max)

G

H

J (max)

A75

8.74

3.30

23.80

8.74

3.66

23.80

14

7.87

29.05

14

7.87

29.05

B75

8.56

3.88

23.00

8.84

4.25

23.30

14

8.46

28.46

14

8.46

28.46

C75

8.56

3.88

23.00

8.84

4.25

23.30

14

8.46

28.46

14

8.46

28.46

G75

9.29

4.49

24.13

9.56

4.80

24.40

14

9.05

28.85

14

9.05

28.85

J75

9.29

4.49

24.13

9.56

4.80

24.40

14

9.05

28.85

14

9.05

28.85

P75*

8.56

3.30

22.56

8.84

3.66

22.83

14

7.87

28.03

14

7.87

28.03

*  316 / 316L stainless steel only

Carbon steel and Stainless steel chambers with 2" and NW 50 (DIN) connections.

mm

2" NPT

2" socket weld

2" or NW 50

2" or NW 50

Flanged upper side / bottom

Flanged side / side

Part n° code

A

B

C (max)

A

B

C (max)

D

E

F (max)

G

H

J (max)

A75

222

84

605

222

101

605

356

200

738

356

200

738

B75

211

98

584

228

115

601

356

220

729

356

220

729

C75

211

98

584

228

115

601

356

220

729

356

220

729

G75

231

115

614

248

132

631

356

235

739

356

235

739

J75

231

115

614

248

132

631

356

235

739

356

235

739

P75*

211

84

576

228

101

593

356

200

721

356

200

721

inches

2” NPT

2" socket weld

2" or NW 50

2" or NW 50

Flanged upper side / bottom

Flanged side / side

Part n° code

A

B

C (max)

A

B

C (max)

D

E

F (max)

G

H

J (max)

A75

8.74

3.31

23.80

8.74

3.97

23.80

14

7.87

29.05

14

7.87

29.05

B75

8.33

3.88

23.00

9.00

4.55

23.66

14

8.66

28.70

14

8.66

28.70

C75

8.33

3.88

23.00

9.00

4.55

23.66

14

8.66

28.70

14

8.66

28.70

G75

9.11

4.53

24.17

9.78

5.20

24.84

14

9.25

29.09

14

9.25

29.09

J75

9.11

4.53

24.17

9.78

5.20

24.84

14

9.25

29.09

14

9.25

29.09

P75*

8.33

3.31

22.67

9.00

3.97

23.34

14

7.87

28.38

14

7.87

28.38

*  316 / 316L stainless steel only

Summary of Contents for 075

Page 1: ...eactivating the switch Rising level Falling level pivot return spring UNPACKING Unpack the instrument carefully Inspect all units for dam age Report any concealed damage to carrier within 24 hours Check the contents of the packing slip and purchase order Check and record the serial number for future refer ence when ordering parts AGENCY APPROVALS Agency Approval CENELEC EEx d IIC T6 explosion proo...

Page 2: ...pecific gravity Pressure rating Models with material construction code bar C PSIG F 4 40 C 230 C 400 C 100 F 450 F 750 F A 0 65 42 7 29 0 25 2 620 420 365 B 0 75 69 0 58 6 51 7 1000 850 750 C 0 60 34 5 22 4 19 6 500 325 285 G 0 57 51 7 38 6 32 7 750 560 475 P 0 75 27 6 17 9 15 5 400 260 225 O 0 85 27 6 22 4 19 6 400 325 285 MATERIALS OF CONSTRUCTION SIZE AND TYPE OF TANK CONNECTIONS see configurat...

Page 3: ... 2 EEA E1A EZ8 EOD EO8 EY8 EO7 EY7 EEB E1B EZ7 EOM EO6 EY6 EO5 EY5 Series 2 400 C 1 2AA 22A 23A 2KD 2K8 2U8 2K7 2U7 2AB 22B 23B 2KM 2K6 2U6 2K5 2U5 Vibr resistant 750 F SPDT 2 2BA 24A 25A 2LD 2L8 2V8 2L7 2V7 2BB 24B 25B 2LM 2L6 2V6 2L5 2V5 mercury switch 3 2CA 26A 27A 2MD 268 278 267 277 2CB 26B 27B 2MM 266 276 265 275 with DPDT 1 2DA 28A 29A 2ND 2N8 2X8 2D7 2W7 2DB 28B 29B 2NM 2N6 2X6 2D5 2W5 bea...

Page 4: ...ore responsive and accurate level change in the control Liquid in a long line may be cooler and more dense than liquid in the vessel causing lower level indication in the control than actual level in the vessel Most mechanical control switch housings are designed to allow 360 positioning of the cable entries by loosening the set screw s See figure 4 On high temperature applica tions above 120 C 25...

Page 5: ... 5 5 Perform system shut down procedures as required to relieve pressure from float chamber of control Allow unit to cool a Close shut off valves if so equipped to isolate control from tank Drain off liquid in float chamber See Figure 3 on page 4 b On installations without shut off valves relieve pressure from the tank Drain liquid in tank to a level below the connections of the float chamber NOTE...

Page 6: ...avoid are observed your control will provide reliable protection of your capital equipment for many years WHAT TO DO 1 Keep control clean NEVER leave switch housing cover off the control This cover is designed to keep dust and dirt from interfering with switch mechanism operation In addition it protects against damaging moisture and acts as a safety feature by keeping bare wires and terminals from...

Page 7: ...in two place 90 apart Refer to Figure 3 on page 4 7 If mechanism is equipped with a mercury switch examine glass mercury tube closely as previously described in Preventive Maintenance section If switch is damaged replace it immediately 8 If switch mechanism is operating satisfactorily proceed to check sensing unit CHECK SENSING UNIT 1 Check to be certain liquid is entering float chamber A valve ma...

Page 8: ... 05 B75 47 1 88 67 2 63 C75 41 1 61 64 2 51 G75 38 1 50 58 2 28 P75 36 1 41 60 2 36 Part n mm inches code HL LL A75 25 0 98 52 2 05 B75 59 2 31 79 3 11 C75 53 2 08 76 3 00 G75 46 1 88 66 2 60 P75 48 1 88 72 2 83 Part n mm inches code HL LL A75 25 0 98 52 2 05 B75 76 3 00 96 3 77 C75 70 2 77 93 3 63 G75 64 2 50 84 3 30 075 75 2 94 103 4 05 P75 65 2 56 89 3 50 1 and NW 25 DIN connections NPT flanged...

Page 9: ...EMA 7 9 1 NPT F entry BASEEFA CENELEC M20 x 1 5 or 3 4 NPT F entry Pneumatic switches K Series Nema 3R 1 4 NPT F two entries J Series Nema 3R 1 4 NPT F one entry Rotation clearance L NEMA 4X IP 65 109 4 29 NEMA 7 9 100 3 94 BASEEFA CENELEC 110 4 33 Pneumatic K NEMA 3R 130 5 12 Pneumatic J NEMA 3R 110 4 33 All housings rotatable 360 Allow 200 mm 7 87 overhead clearance for cover removal Threaded so...

Page 10: ... 356 230 733 P75 217 84 573 224 93 580 356 200 712 356 200 712 inches 1 1 2 NPT 1 1 2 socket weld 1 1 2 or NW 40 1 1 2 or NW 40 Flanged upper side bottom Flanged side side Part n code A B C max A B C max D E F max G H J max A75 8 74 3 30 23 80 8 74 3 66 23 80 14 7 87 29 05 14 7 87 29 05 B75 8 56 3 88 23 00 8 84 4 25 23 30 14 8 46 28 46 14 8 46 28 46 C75 8 56 3 88 23 00 8 84 4 25 23 30 14 8 46 28 4...

Page 11: ...units only with all parts listed under items 4 through 10 assembled When ordering specify model serial number of control Item Description Models with mat l code 4 A B C G J O P75 1 Housing cover Housing Refer to bulletin 42 780 for switch housing cover and base assemblies 2 Housing base kits 3 Switch mechanism Refer to bulletin on switch mechanism furnished listed on page 4 4 Jam nuts 5 Guide wash...

Page 12: ...odels in the field Switch actuation levels have been set at the factory to meet specific customer specifications Variations in actual conditions from design conditions usually requires special control modifications Consult the factory or your local representative for assistance REPLACEMENT OF FLOAT AND STEM ASSEMBLIES Should replacement of either upper or lower float and stem assembly be required ...

Page 13: ...13 ...

Page 14: ...E So that we may efficiently process any materials that are returned it is essential that a Return Material Authorisation RMA form will be obtained from the factory It is mandatory that this form will be attached to each material returned This form is avail able through Magnetrol s local representative or by contacting the factory Please supply the following information 1 Purchaser Name 2 Descript...

Reviews: