1.4.1  Operating Modes/ Switching point 

The digital counter can be set to Operating Mode “OPEN SPACE COUNT” or " PASSING VEHICLE COUNT“ . 

The two options can be selected by setting the Count threshold to: 
Threshold = 0 (Default) 

 Mode “OPEN SPACE COUNT”  

       see 1.4.1.1 

Threshold = 1 = 1..9999  

 Mode " PASSING VEHICLE COUNT“   see 1.4.1.2 

 

Display

 

Status Setting 

1234

 

Normal Operation 

M long 

SµS

  

 

S  oc

  = Threshold 

S  oc

   

1234 

Alternating

 

Display 

Count Threshold 

 

M short 

 next, next Menu item 

M long 

End

  = back to normal operation

 

 or 

  

 Change Threshold 

1234 

one digit 

flashes

 

Change Threshold 

0...9999 

 or 

  

 Digit + / - 1

 

 or 

 1 sec. 

 Fast scroll

 

 or 

 3 sec.

 

 10’s 

 100’s 

 1000’s

 

M short 

 100’s 

 10’s 

 1’s 

 Cancel 

M

 

long 

Skor

  = save 

 

1.4.1.1  Operating Mode “OPEN SPACE COUNT“ 

The “OPEN SPACE COUNT” is preferably used when the control audit count of the parking spaces is done when 

the car-park is full so less open spaces has to be counted. Vehicles leaving the car-park will increment the count 

(Input 1) and vehicles entering the facility will decrement the count (Input 2). The counter will activate the 

output relay whenever the open space count is equal or less than “0”.  The output relay will be released as soon 

the count reached the adjusted count hysteresis. 

1.4.1.2  Operating Mode  „PASSING VEHICLE COUNT“ 

The “PASSING VEHICLE COUNT” is preferably used when the control audit count of the parking spaces is done 

when the car-park is empty so less occupied parking spaces must be counted.  Vehicles entering the car-park will 

increment the count (Input 1) and vehicles leaving the facility will decrement the count (Input 2). The counter 

will activate the output relay whenever the vehicle count reaches or is higher than the adjusted maximum. The 
output relay will be released as soon the count reaches or is lower than the adjusted lower count hysteresis. 

  

 

1.4.2 Count Hysteresis 

With the count hysteresis you can set the amount of vehicles that have to leave the facility after the “OPEN 

SPACE COUNT” or the “PASSING VEHICLE COUNT” have reached the maximum and triggered the output relay. 

Factory default is 1. 

 

Display

 

Status Setting 

1234

 

Normal Operation 

M long 

SµS

 

 

S  oc

 

M 1 x short 

HµS

  = Count hysteresis 

HYS       

 

1234 

Alternating

 

Display 

Count hysteresis 

 

M short 

 next, next menu item 

M long 

End

  = return to normal operation

 

 Or 

  

 Change Count hysteresis 

1234 

One flashing 

digit

 

Change Count 

hysteresis 

1...9999 

 Or 

  

 digit + / - 1

 

 Or 

 1 sec. 

 fast scroll

 

 Or 

 3 sec.

  

 10’s 

 100’s 

 1000’s

 

M short 

 100’s 

 10’s 

 1’s 

 cancel 

M

 

long 

Skor

  = save 

 

Summary of Contents for VEK CN1

Page 1: ...1 1 Operating Instructions DIGITAL COUNTER VEK CN1 Version 2002_03...

Page 2: ...g instructions and on any alterations and extensions that may be relevant Please read these operation instructions prior to installing the equipment COPYRIGHT 2001 Magnetic Automation Corp All rights...

Page 3: ...____________________7 1 4 System menu Installation specific Settings ________________________________________ 8 1 4 1 Operating Modes Switching point __________________________________________________...

Page 4: ...4 digit display Totalize counter 999 bis 9999 4 noise immunity inputs each function Reset individually adjustable 1 Reset input optional 1 Relay output 250V 5A for Traffic lights and Lot Full signs o...

Page 5: ...ount must be checked and if necessary updated Display Status Setting 1234 Flashing Return after loss of power or Update open space count M Confirm existing count is correct 1 2 3 Display during normal...

Page 6: ...ormal Operation or First digit flashing modify counter 1234 One digit flashing Modify Counter or Digit 1 or 1 sec Fast scroll or 3 sec 10 s 100 s 1000 s M short 100 s 10 s 1 s Cancel M long Skor saved...

Page 7: ...eset Input counter M short Cancel reset Note 1 The open space or quantity of passed vehicles count will not be effected during reset of any of the input counts 3 If one of the four 4 input counter dis...

Page 8: ...ng Count hysteresis 1 250 M short next menu item SkP 1234 Alternating Upper Count threshold 0 9999 SkP_ 123 Alternating Lower Count threshold 0 999 or change M long save inP1 4 Alternating Add Sub rEs...

Page 9: ...relay will be released as soon the count reached the adjusted count hysteresis 1 4 1 2 Operating Mode PASSING VEHICLE COUNT The PASSING VEHICLE COUNT is preferably used when the control audit count of...

Page 10: ...he default is 9999 for the upper and 999 for the lover level Display Status Setting 1234 Normal Operation M long S S S oc M 2 x short SkP upper level 0 9999 M short SkP_ lover level 999 0 SkP _ 1234 A...

Page 11: ...nge Function no F rEs Sub Add Add Sub rEs no F M short Cancel M long Skor save Factory default is Incrementing for Input 1 and 3 and decrementing for Input 2 and 4 1 4 5 Output settings The output rel...

Page 12: ...to factory default using following procedure Display Status Setting Turn off power to the unit for longer then 2 seconds 1234 Flashing Return after power failure Press two buttons simultaneously Err...

Page 13: ...he control boards please use electrostatic save measurements to prevent any damage to the components Do not touch the board or any of the components Internal supply is does not use the External supply...

Page 14: ...Using one of the inputs as count reset input all counts can be reset to 0 when a signal is applied According to the relay output setting the relay switches to OPEN or OCCUPIED The reset does not effec...

Page 15: ...C Storage Temperature 40 C to 70 C Humidity max 95 non condensing Count Total 999 bis 9 999 Per count input up to 9 999 9999 Inputs Opto Coupled 4 Inputs Minimum input time 50ms Input current 5mA at 1...

Reviews: