1.4.1 Operating Modes/ Switching point
The digital counter can be set to Operating Mode “OPEN SPACE COUNT” or " PASSING VEHICLE COUNT“ .
The two options can be selected by setting the Count threshold to:
Threshold = 0 (Default)
→
Mode “OPEN SPACE COUNT”
see 1.4.1.1
Threshold = 1 = 1..9999
→
Mode " PASSING VEHICLE COUNT“ see 1.4.1.2
Display
Status Setting
1234
Normal Operation
M long
→
SµS
→
S oc
= Threshold
S oc
1234
Alternating
Display
Count Threshold
M short
→
next, next Menu item
M long
→
End
= back to normal operation
∧
or
∨
→
Change Threshold
1234
one digit
flashes
Change Threshold
0...9999
∧
or
∨
→
Digit + / - 1
∧
or
∨
1 sec.
→
Fast scroll
∧
or
∨
3 sec.
→
10’s
→
100’s
→
1000’s
M short
→
100’s
→
10’s
→
1’s
→
Cancel
M
long
→
Skor
= save
1.4.1.1 Operating Mode “OPEN SPACE COUNT“
The “OPEN SPACE COUNT” is preferably used when the control audit count of the parking spaces is done when
the car-park is full so less open spaces has to be counted. Vehicles leaving the car-park will increment the count
(Input 1) and vehicles entering the facility will decrement the count (Input 2). The counter will activate the
output relay whenever the open space count is equal or less than “0”. The output relay will be released as soon
the count reached the adjusted count hysteresis.
1.4.1.2 Operating Mode „PASSING VEHICLE COUNT“
The “PASSING VEHICLE COUNT” is preferably used when the control audit count of the parking spaces is done
when the car-park is empty so less occupied parking spaces must be counted. Vehicles entering the car-park will
increment the count (Input 1) and vehicles leaving the facility will decrement the count (Input 2). The counter
will activate the output relay whenever the vehicle count reaches or is higher than the adjusted maximum. The
output relay will be released as soon the count reaches or is lower than the adjusted lower count hysteresis.
1.4.2 Count Hysteresis
With the count hysteresis you can set the amount of vehicles that have to leave the facility after the “OPEN
SPACE COUNT” or the “PASSING VEHICLE COUNT” have reached the maximum and triggered the output relay.
Factory default is 1.
Display
Status Setting
1234
Normal Operation
M long
→
SµS
→
S oc
M 1 x short
→
HµS
= Count hysteresis
HYS
1234
Alternating
Display
Count hysteresis
M short
→
next, next menu item
M long
→
End
= return to normal operation
∧
Or
∨
→
Change Count hysteresis
1234
One flashing
digit
Change Count
hysteresis
1...9999
∧
Or
∨
→
digit + / - 1
∧
Or
∨
1 sec.
→
fast scroll
∧
Or
∨
3 sec.
→
10’s
→
100’s
→
1000’s
M short
→
100’s
→
10’s
→
1’s
→
cancel
M
long
→
Skor
= save