Magnetic Autocontrol VEK CN1 Operating Instructions Manual Download Page 13

 

13

/

13

 

 

2 Installation Instructions 

2.1 Input voltage 

All inputs are provided with Opto couplers. To activate the inputs you can either use the internal switching 

voltage or use an external supply. When using an external supply you must first change the internal jumper 
setting of the control board. To do so carefully open the controller housing and set the jumper J2 in accordance 

with the drawing and table below.  

 
    

Attention!

 

The control board consists of electrostatic sensitive components. If working on the control boards 

please use electrostatic save measurements to prevent any damage to the components. Do not touch the board 

or any of the components!  

 

Internal supply is does not use the  

External supply uses the 

 

Opto couplers. 

Opto couplers. 

 
 

 

 

Power Supply 

Input power 

Attention 

12..24V DC  

Internal 

Jumper J2 to the left 

• 

ONLY ONE POWER SUPPLY FOR ALL COUNTERS 

• 

DO NOT CONNECT TERMINAL „C“. THE INPUTS ARE 
CONNECTED TO GROUND (0V). 

12..24V AC 

Internal 

Jumper J2 to the left 

• 

DO NOT CONNECT MULTIPLE COUNTERS IN PARALLEL! 

12..24V AC oder DC 

External 12..24V DC 

Jumper J2 to the right 

• 

USE ONLY ONE EXTERNAL POWER SUPPLY FOR ALL 

INPUTS! 

 

 

J2

C

R,I1..I4

12..24V DC

alternativ

J2 

C R,I1..I4 

alternativ 

either  

 5 mA at 12V,  

 10mA at 24V 

Summary of Contents for VEK CN1

Page 1: ...1 1 Operating Instructions DIGITAL COUNTER VEK CN1 Version 2002_03...

Page 2: ...g instructions and on any alterations and extensions that may be relevant Please read these operation instructions prior to installing the equipment COPYRIGHT 2001 Magnetic Automation Corp All rights...

Page 3: ...____________________7 1 4 System menu Installation specific Settings ________________________________________ 8 1 4 1 Operating Modes Switching point __________________________________________________...

Page 4: ...4 digit display Totalize counter 999 bis 9999 4 noise immunity inputs each function Reset individually adjustable 1 Reset input optional 1 Relay output 250V 5A for Traffic lights and Lot Full signs o...

Page 5: ...ount must be checked and if necessary updated Display Status Setting 1234 Flashing Return after loss of power or Update open space count M Confirm existing count is correct 1 2 3 Display during normal...

Page 6: ...ormal Operation or First digit flashing modify counter 1234 One digit flashing Modify Counter or Digit 1 or 1 sec Fast scroll or 3 sec 10 s 100 s 1000 s M short 100 s 10 s 1 s Cancel M long Skor saved...

Page 7: ...eset Input counter M short Cancel reset Note 1 The open space or quantity of passed vehicles count will not be effected during reset of any of the input counts 3 If one of the four 4 input counter dis...

Page 8: ...ng Count hysteresis 1 250 M short next menu item SkP 1234 Alternating Upper Count threshold 0 9999 SkP_ 123 Alternating Lower Count threshold 0 999 or change M long save inP1 4 Alternating Add Sub rEs...

Page 9: ...relay will be released as soon the count reached the adjusted count hysteresis 1 4 1 2 Operating Mode PASSING VEHICLE COUNT The PASSING VEHICLE COUNT is preferably used when the control audit count of...

Page 10: ...he default is 9999 for the upper and 999 for the lover level Display Status Setting 1234 Normal Operation M long S S S oc M 2 x short SkP upper level 0 9999 M short SkP_ lover level 999 0 SkP _ 1234 A...

Page 11: ...nge Function no F rEs Sub Add Add Sub rEs no F M short Cancel M long Skor save Factory default is Incrementing for Input 1 and 3 and decrementing for Input 2 and 4 1 4 5 Output settings The output rel...

Page 12: ...to factory default using following procedure Display Status Setting Turn off power to the unit for longer then 2 seconds 1234 Flashing Return after power failure Press two buttons simultaneously Err...

Page 13: ...he control boards please use electrostatic save measurements to prevent any damage to the components Do not touch the board or any of the components Internal supply is does not use the External supply...

Page 14: ...Using one of the inputs as count reset input all counts can be reset to 0 when a signal is applied According to the relay output setting the relay switches to OPEN or OCCUPIED The reset does not effec...

Page 15: ...C Storage Temperature 40 C to 70 C Humidity max 95 non condensing Count Total 999 bis 9 999 Per count input up to 9 999 9999 Inputs Opto Coupled 4 Inputs Minimum input time 50ms Input current 5mA at 1...

Reviews: