Operating Instructions
581E,5005/6.00
-
13 -
5.1. Command generators: their connection and
function in the different operating modes
Important note: All command generators (e.g. push buttons, light barriers, limit
switches) must be connected as voltage-free contacts. Contact Magnetic for advice
before connecting command generators with open collector outputs.
Program 1 (Mode 3):
The gate is controlled by two switches.
Wiring of the switches see wiring diagram S1 and S2.
The switch for OPEN is prior to the DOWN switch, that means we both contacts are
closed, the gate will open.
Connections:
Potential-free contact b24V (terminal S) and terminal 9 (S1) and terminal
10 (S2).
Additional safety devices can be connected to terminal 14 and 13. These must
function as break contacts.
Program 2 (Mode 4):
The barrier is opened and closed by two separate command generators (pulsed).
Open:
contact b24V (terminal S) and terminal 10 (S2).
Close:
contact b24V (terminal S) and terminal 9 (S1).
Additional safety devices can be connected to terminal 14 and 13. These must function as
break contacts.